Ku nst sto ffschweißtec hni k
Starting and operating
Chapter 5
02.08.2011
Working Instructions WIDOS 4900 CNC 3.5
Page 33 of 68
5.12. Error messages
If during the work with the machine
•
the prescriptions of the DVS are not followed;
•
the working steps necessary for the welding process are not correctly or not at all
performed;
•
certain measuring devices do not function,
the following error messages will appear on the display:
T
Heating element temperature
A
Adjusting
W
Heating
U
Change over
R
Pressure build-up ramp
t
Joining time
p
Joining pressure
5.13. Administration of the welding data
The battery-buffered CNC memory (RAM) can store about 400 weldings.
Make sure not to go over this quantity (in the display the error message
"memory full“ appears) because otherwise the first stored welding will be over-
written.
If necessary, copy the welding data on SD-card and read out in time.
5.13.1. Copying internal data onto SD-card and deleting them (RAM)
Abort and back to basic menu by pressing <C>.
One menu item back by pressing <Enter> (keep pressed) and <->.
Display:
2. line:
WIDOS 4900 CNC
09:43 03.05.2007
basic menu
next menu by pressing <Enter> button
Display:
2. line:
copy
_
By pressing <+> the data from the internal memory is transferred to the
SD-card.
In case of an error, these error codes will
also appear in the first line of the display.
All error messages are logged.