Ku nst sto ffschweißtec hni k
Operating and indicating elements
Chapter 4
03.03.2009
Working Instructions WIDOS PSM 15 with pneumatic clamping
Page 14 of 33
No.
Denomination
Function
14 Hand lever valve on the right (optional)
- to clamp / release clamping beam right side
15 Hand lever valve on the left (optional)
- to clamp / release clamping beam left side
4.1. Components at the heating element
(View of heating element from the rear, only with basic frame)
No.
Denomination
Function
12 On/off-switch with red
lamp
- as soon as the heating element is activated, it is heated up.
- lamp is red if connected to the mains
13 D rotary
regulator
- temperature adjustment for the heating element
14 Control lamp, green
We distinguish between 3 conditions:
•
ON
: signal for the state that the heating element does not heat up
or cool down at the moment.
•
Blinking:
The temperature of the heating element is maintained.
This is realized by the pulse-interval relation.
•
Off:
signal for the state that the heating element is heated up at
the moment. The nominal temperature is not yet reached.
15 Connection cable
- cable for the connection with local power supply 230 V / 50 Hz,
covering 16 A
The heating element shown in welding position is descended below by slewing the lever (5) in
direction of the arrow.
(5)
16
17
18
19