Ku nst sto ffschweißtec hni k
Operating and indicating elements
Chapter 4
03.03.2009
Working Instructions WIDOS PSM 15 with pneumatic clamping
Page 15 of 33
4.2. How to clamp the sheet
Each sheet is inserted between the clamping beams and the basic plate and afterwards
clamped. The following picture shows the left clamping beam (in the front) in opened and the right
one (at the rear) in closed position.
In order to clamp release the cylinder by the foot valve or by the optional hand lever valve. Swivel
out the connecting rod to the front. Lift the clamping beam at the front handle and push it to the
rear until the beam props in the mouth (image below).
Place the plastic sheet onto the basic sheet. Shortly lift the clamping beam, pull it out of the
supporting mouth and place it onto the plastic sheet. Swivel the connecting rod into the mouth at
the clamping beam and clamp the plastic sheet by the foot valve or by the optional hand lever
valve.
(Image rear clamping beam)
(Image showing clamping beam supported with
manual clamping)
Cylinder released and connecting rod swivelled out
Left clamping beam open
Basis plate
Right clamping beam shut
Clamping beam shut
Clamping beam props in the mouth