Operating and indicating elements
Chapter 4
03.03.2009
Working Instructions WIDOS PSM 15 with pneumatic clamping
Page 16 of 33
There is acute danger of jamming and crushing!
•
Only activate the foot valve (optional hand lever valves) to clamp if no body part
or strange object is within the clamping area.
4.3. Service unit
Activate valve by turning.
The service unit (LFR-1/8-D-MINI-KC) regulates the fed compressed air onto the adjusted
working pressure and compensates pressure fluctuations. It clears the compressed air from dirt
particles and condensation water. It is not intended for the use of other media (liquids or gases).
In order to adjust the regulator:
•
slowly ventilate device.
•
pull the pressure regulator button for the unlocking upwards (away from housing).
•
Turn the pressure regulator button until the desired pressure is shown on the pressure gauge.
The input pressure must be at least 1 bar larger than the output pressure.
•
Press the pressure regulator button downwards (towards the housing). Thereby, it is secured
against unintentional twisting.
Activating valve
Pressure regulator
button with pressure
gauge
Connection for
compressed air
hose
Manual outlet for
condensation water