Ku nst sto ffschweißtec hni k
Starting and operating
Chapter 5
03.03.2009
Working Instructions WIDOS PSM 15 with pneumatic clamping
Page 20 of 33
•
After the erection of the welding force press the stopwatch.
During the cooling down adjust the force if necessary once again (the cooling down force is
the same as the adjusting force).
•
After the cooling down time has elapsed, remove the force.
•
release the clamping beams with the optional foot valves or hand lever valves and swivel it
open.
•
Take out the welded piece.
•
Then open the machine.