Page 28
Issue 5.2 – March 2016
6
Commissioning
!
DANGER
Electrical hazard!
Work on electrical installations may only be carried out by a qualified
electrician.
!
CAUTION
Initial commissioning may only be carried out by trained service per-
sonnel.
IMPORTANT
Observe the safety instructions in chapter 3 and the safety data
sheets for all work on the inkjet printer.
6.1
Prerequisites
!
CAUTION
•
The printer must be installed in well aired rooms.
•
The printer must be set up stable. If the printer is set on a
WIEDENBACH wheeled underframe, it has to be fastened with
safety elements on the surface.
•
The power connector on the printer housing is used as a safety
separator acc. to IEC60950 and must be easily accessible
•
Lay down print head hose and connection cable so that no per-
sons can get caught.
•
The difference in height between the printer and the printing head
may be a maximum 3 m.
•
The floor must be sealed liquid-tight and resistant to solvents.
•
There must be a washing facility close to the inkjet printer.
•
Space requirement see chapter 2.