Setting the agitator unit tilt angle
➢
Turn the tension jack (
1
) on the drawbar to set one of
the following positions.
➢
Observe the spirit level (
2
) when doing so.
Position „0“
•
on regularly maintained grounds with coarse dirt
•
for dry conditions with fibre content
Position „ + “ = nach hinten ansteigend
•
new or highly filled grounds with low dirt proportion
•
on regularly maintained grounds with low proportion of coarse dirt
•
for deeper surface cleaning
•
for dew coverage and flat surface cleaning
Position „ –„ = nach hinten abfallend
•
•
grounds which are not regularly maintained with broken fibre content
•
for dry conditions and flat surface cleaning
•
for flat processing with leaf coverage
8.2.4
Adjusting the baffle lugs at the front
When delivered, the impact flaps are set to the lowest position.
➢
When using worn strip brushes, the impact flaps must
be set on a level, solid surface.
The clearance (measurement
X
) from the bottom edge of the
impact flaps to the ground should be at least 10 mm more than
the distance from the strip brush to the ground.
8.3.
Changing the vibrating screen
8.3.1
Option
–
vibrating screen
•
Riddle screen with 6 mm holes (Standard)
•
Riddle screen with 5 mm holes (Option)
•
Riddle screen with 8 mm holes (Option)