Configuration and setup
Wieland Electric GmbH | BA000870 | 06/2020 (Rev. A)
22
5.5.3
COM configuration: Advanced settings
For advanced details of COM port setting, you can click on the
Advanced Settings
button at the end
of the
Serial Settings
page which will open another web browser window as shown in Figure 18. The
description of each option is explained as follows.
Figure 18: COM 1 Advanced Settings web page
TCP
•
TCP timeout:
By clicking the
Enable
box of
TCP Timeout
and input value in seconds between 0
and 60000,
wienet SDS
will check if there's any data from serial port. If time expired,
wienet SDS
will disconnect from its peer.
•
TCP Keep-alive:
By clicking the
Enable
box of
TCP Keep-alive
and input value in seconds
,
wienet SDS
will check if its peer is still alive. Noted that it will retry 3 times and timeout is 5 sec-
onds in default.