The motor is however placed under a greater load than
permitted. The boost factor must therefore be set carefully (see
flow chart on page 6-27).
Nominal current
Nominal motor power (kW)
Nominal current value (decimal)
0.11 39
0.15 45
0.18 50
0.25 61
0.37 80
0.55 109
0.75 140
Adjustable value range (decimal) 1…255
Value range (physical variable)
internal variable
Recommended values
see table
Used to protect the motor by setting the maximum current.
Mains frequency
Adjustable value range (decimal) 50 Hz or 60 Hz
Value range (physical variable)
50 Hz or 60 Hz
Recommended values
Europe: 50 Hz (default)
USA: 60 Hz
The setting of the mains frequency is used for adaptation to
country-specific conditions.
Recommended values for
nominal current for standard
three-phase asynchronous
motors up to 0.75 kW