EN
35
Measuring
range
Resolution
Accuracy
Capacity test
6.000 nF
0.001 nF
±(10 % of m.v. + 25D)
60.00 nF
0.01 nF
±(2 % of m.v. + 10D)
600.0 nF
0.1 nF
±(1.5 % of m.v. + 5D)
6.000 μF
1 nF
±(1.5 % of m.v. + 5D)
60.00 μF
10 nF
±(1.5 % of m.v. + 5D)
600.0 μF
100 nF
±(2 % of m.v. + 10D)
6.000 mF
1 μF
±(10 % of m.v. + 25D)
60.00 mF
10 μF
±(10 % of m.v. + 25D)
Frequency
600.0 Hz
0.1 Hz
±0.1 % + 1D
6.000 kHz
1 Hz
60.00 kHz
10 Hz
600.0 kHz
100 Hz
6.000 MHz
1 kHz
60.00 MHz
10 kHz
Temperature
measurement
-200...1.350 °C
±(10 % of m.v. + 1D)
Data HOLD
yes
RELATIVE value
measurement
yes
MIN/MAX
measurement
yes
Auto/Manual RANGE
selection
yes
DMM battery LOW
indication
yes
NCV measurement
(Non-contact AC
electric field detection)
yes
True RMS
yes
Backlight
yes
Display
6.000 counts, bargraph
IP rating
IP40
Battery
AAA 2x 1.5 V; R03
Fuse
Ceramic fuses; F 600 mA/1,000 V and F 10 A/1,000 V
Standards
EN 61010-1, EN 61010-02-033, EN 61010-031,
EN 61326
Overvoltage category
CAT IV/600 V; CAT III/1,000 V
Pollution degree
2
Operating temperature
0...50 °C
Storage temperatur
-10...60 °C
Note: The lowest ranges are specified from 5 % of the range.
Note: AC Voltage and AC Current ranges are specified up to 400 Hz.