background image

2

Before using the heater, please read the instructions carefully. In the future 

it will benefit by its failure-free operation for a long time.

Flow water heaters series POW-LCD MULTI are intended for heating tap water. They can sup-

ply hot water to several water outlets located in different rooms. These heaters are equipped 

with heating coils which are directly washed by water. Such direct process of heating prevents 

scale formation and ensures high efficiency and speed of heating water. The microprocessor 

system analyses the temperature of inlet and outlet water, the set temperature, and water 

consumption of the user. Based on the collected data, it increases or decreases the heating 

power in such a way that the water temperature at the outlet corresponded to the temperature 

set by the user. Such control of the heater operation ensures the comfort of use and energy 

saving. Additionally, the heater is equipped with the possibility of choosing rated power. It is 

equipped with air lock sensors which limit, to the minimum, the possibility of damage of the 

heating elements due to air locking of the water distribution system, as well as the system 

adjusting the temperature drop caused by the drop of supply voltage.

Heaters can additionally heat water that was pre-heated, e.g. with the use of the solar system 

which at the heater inlet cannot exceed 60

O

C.

•  The device cannot be installed in rooms in which the temperature may 

fall below 0

O

C and in which there is the risk of explosion.

•  This equipment is not intended to be used by persons (including chil-

dren) of lower physical, sensory or mental capability, unless they operate 

it under supervision.

•  Attention should be paid to children not playing with the equipment.

Installation instructions 

The installation and start-up of the POW-LCD MULTI heater should be done by a person 

qualified in accordance with the guidelines contained in the Manual. All installation works 

should be carried out with disconnected power and water supplies. The heater electrical instal-

lation should be conducted in accordance with the binding regulations. The device should be 

permanently connected to electrical wiring with ground terminal. The electrical wiring should 

be equipped with residual current circuit breaker protecting against electric shock and with a 

switch ensuring the disconnection of the device from the power source, in which the distance 

between the contacts should be not less than 3 mm.

1.   To the place in which the heater is to be installed lead electrical wiring and water distribu-

tion system, using for that the mounting template.

2.   Drill holes and mount expansion plugs.

3.   Install the control valve with a filter on cold water supply (Fig. 3).

4.   Unscrew the fastening screw which holds the housing of the heater located at the bottom 

of it (Fig. 1), take off the cover and disconnect the ribbon cable by taking the plug out of 

the socket marked “LCD” (Fig. 2).

5.   Select rated power by transferring the link to a proper place on a contact marked MOC 

according to the description on the sticker. 

6.   Screw the heater to the wall with the use of fastening screws, having earlier run the power 

cable through the hole.

7.   Check the starting of pressure switch.

Summary of Contents for Type POW-LCD MULTI

Page 1: ...Flow water heaters type POW LCD MULTI INSTALLATION AND OPERATION MANUAL ...

Page 2: ...quipment is not intended to be used by persons including chil dren of lower physical sensory or mental capability unless they operate it under supervision Attention should be paid to children not playing with the equipment Installation instructions The installation and start up of the POW LCD MULTI heater should be done by a person qualified in accordance with the guidelines contained in the Manua...

Page 3: ...lectrical wiring in accordance with Figure 4 12 Connect the ribbon cable by inserting the plug with the proper side to the socked marked LCD see Fig 2 13 Put on the housing and screw it with a fastening screw Fig 2 Display board with ribbon cable 1 Plug 2 Socket marked LCD 3 Display board Fig 1 Heater housing 1 Display 2 Button increasing the set temperature 3 Button decreasing the set temperature...

Page 4: ... the hot water valve waiting till the device has achieved full operational readiness approx 5 seconds beginning the process of heating in the lower part of display lines will be shown indicating in percent the heating power of the heater Close the hot water valve The heating process is automatically turned off the lines previously indicating the heating power will disappear from the display Fig 4 ...

Page 5: ...easures temperature of outlet water every 10 seconds If two temperature measurements are the same it means the temperature has stabilized and the electronic system can compare it with the set temperature In case when the obtained temperature is smaller from the set temperature due to the drop of the mains voltage the heater increases the power automatically so that the water temperature achieved t...

Page 6: ...mmed temperature will be displayed and thereby the set temperature with which the heater is to heat the water In order to re program any of the buttons T1 T2 T3 follow the instructions given in points 1 and 2 Display service mode The simultaneous pressing of buttons marked and for about 1 second will make the display shift from the basic mode the information about the set temperature and power is ...

Page 7: ...e socket marked LCD Fig 2 3 Close the control valve marked 1 4 Unscrew the control valve plug marked 2 5 Take out the mesh filter marked 3 6 Remove dirt 7 Insert the mesh filter 8 Screw the valve plug 9 Open the control valve and check the tightness of connections 10 Connect the ribbon cable of the display board Fig 2 11 Close the housing 12 Remove entrapped air from the heater and then start it i...

Page 8: ...f the electrical wiring powering the heater The heater does not heat the water to the set temperature too big drop of the mains voltage after the start of the heater too big flow of water see point Use The display shows the number bigger than or equal to 75 0 the heater is blocked the heater has an additional thermal protection which works in the following way when outlet water reaches the tempera...

Page 9: ...itch 6 Air lock sensors 7 Inlet water temperature probe 8 Outlet water temperature probe 9 Outlet water thermal switch 10 Pressure switch 11 Terminals will be parts of the pressure switch 12 Hole for inserting the power cord 13 Controller board 14 Supply water pipe cold 15 Outlet water pipe hot 16 Protective conductor terminal ...

Page 10: ...ay board and keyboard 3 flow switch turbine 4 inlet water temperature probe 5 outlet water temperature probe 6 7 flow switch and air lock sensor 8 heating unit 9 heater controller 10 pressure switch PE protective conductor terminal E electrode G1 G2 G3 heating elements ...

Page 11: ...onnecting mm2 4 x 2 5 4 x 2 5 4 x 2 5 4 x 4 4 x 4 4 x 6 Maximum cross section of connecting cables mm2 4 x 10 Rated power of the miniature circuit breaker A 20 20 25 32 32 40 Minimum water resistance at 15O C Ωcm 1300 Pressure of the supplying water MPa 0 1 0 7 Minimum starting flow l min 2 7 Maximum temperature of the supplying water O C 60 Water pipe G Dimensions height x width x depth mm 447 x ...

Page 12: ... point collecting the waste equipment Collection points are run among others by wholesalers or retailers of such equipment as well as by gmina organizational units conducting the activity in the scope of collecting waste The above statutory obligations have been introduced in order to limit the amount of waste created from deteriorated electric and electronic equipment as well as to ensure the pro...