2. Design and function
2. Design and function
2.1 Overview
Electrical connection with protective cap
Electrical connection without protective cap
Case, product label
Process connection, spanner flats
Process connection, thread (depending on version)
2.2 Description
Model E-10: Process connection with internal diaphragm (standard version)
Model E-11:
Process connection with flush diaphragm for highly viscous or crystallising media that may clog the bore
of the process connection.
By means of a sensor element and by supplying power, the prevailing pressure in your application is converted into an
amplified standardised electrical signal via the deformation of a diaphragm. This electrical signal varies in proportion to
the pressure and can be evaluated accordingly.
2.3 Scope of delivery
■
Completely mounted pressure transmitter for flush design (model E-11) with pre-mounted sealings and plastic
protective cap
■
Operating instructions
Cross-check scope of delivery with delivery note.