35
WIKA operating instructions, model GDM-RC-100-T
EN
14499439.01 01/2022 EN/DE
8.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally
compatible way and in accordance with the country-specific waste disposal regulations.
Do not dispose of with household waste. Ensure a proper disposal in
accordance with national regulations.
9. Specifications
Basic information
Measurement principle
Reference gas measurement
Nominal size of the optical display
100 mm
Specifications of the gas density monitor
Measuring range
Measuring range
■
0 ... 10 bar abs. at 20 °C [68 °F] SF₆ gas
■
0 ... 12.5 bar abs. at 20 °C [68 °F] SF₆ gas
Maximum overpressure
1.43 times the measuring range
Minimum bursting
strength
30 bar
Dial
Scale range
End of measuring
range
1.3 bar or 1.8 bar above the first switch point
below the filling pressure
Scale graduation
■
Single scale (divided into sections of different colours)
■
Double scale (divided into sections of different colours)
■
Triple scale (divided into sections of different colours)
Switch contacts
Switch model
Potential-free change-over contact
Number of switches
■
1 switch contact
■
2 switch contact
■
3 switch contact
■
4 switch contact
Up to 4 switch contacts possible as change-over contact
Switching function
Change-over contact
8. Dismounting, return ... / 9. Specifications