29
6 Set up with the display and adjustment module
WIKA Operating Instructions - Process pressure transmitter IPT-1*
Min. adjustment
+000.0 %
=
+0000.0 mbar
0000.0 mbar
2. Set the requested percentage value with
[+]
and
[->]
.
3. Confirm with
[OK]
and edit the requested mbar value.
4. Set the requested mbar value with
[+]
and
[->]
.
5. Confirm with
[+]
and move to max. adjustment with
[->]
.
The min. adjustment is finished.
Information:
For an adjustment with filling, simply enter the actual measured value
indicated at the bottom of the display.
If the adjustment ranges are exceeded, the message "
Outside param-
eter limits
" appears. The editing procedure can be aborted with
[ESC]
or the displayed limit value can be accepted with
[OK]
.
Proceed as follows:
1. Edit the % value in the menu item "
Max. adjustment
" with
[OK]
.
Max. adjustment
+100.0 %
=
+1000.0 mbar
0000.0 mbar
Information:
The displayed pressure for 100 % corresponds to the nominal meas-
uring range of the sensor (in the above example 1 bar = 1000 mbar).
2. Set the requested percentage value with
[->]
and
[OK]
.
3. Confirm with
[OK]
and edit the requested mbar value.
4. Set the requested mbar value with
[+]
and
[->]
.
5. Confirm with
[OK]
and move to the menu overview with
[ESC]
.
The max. adjustment is finished.
Information:
For an adjustment with filling, simply enter the actual measured value
indicated at the bottom of the display.
If the adjustment ranges are exceeded, the message "
Outside param-
eter limits
" appears. The editing procedure can be aborted with
[ESC]
or the displayed limit value can be accepted with
[OK]
.
Process pressure measurement
Set up IPT-1* in the following sequence:
1. Select application "Process pressure measurement"
2. Select the unit of measurement
3. Carry out a position correction
4. Carrying out zero adjustment
Carry out max. adjust-
ment
Parameter adjustment
"Process pressure meas-
urement"