<Key operation>

Phenomenon

Presumed cause and the action

If it is impossible to set.
If the value does
not change by the

,   keys.

• Setting value lock (mode 1 or 2) is designated.
         Release the lock designation.
• During PID auto-tuning or auto-reset.

In the case of PID auto-tuning, cancel the tuning if necessary.

In the case of Auto-reset, it takes approx. 4 minutes

until the auto-reset is completed.

If the setting
indication does not
change in the rated
scale range even if
the  ,   keys
are pressed, and
setting is impossible.

• Main setting value high limit or low limit may be set at the point
  the value does not change.
       Set it again by Auxiliary function setting mode 1.

<Control>

Phenomenon

Presumed cause and the action

If process variable
(temperature) does
not rise.

• Thermocouple or RTD is burnt out.
• Lead wire of thermocouple or RTD is not securely mounted to the
   instrument terminal.
• confirm the connection of the output is securely carried out.

If the main output
remains ON status.

• Main output low limit setting value is set to 100% or greater
   in Auxiliary function setting mode 2.
        Set the value properly.

If the main output
remains OFF status.

• Main output high limit setting value is set to 0% or less
   in Auxiliary function setting mode 2.
        Set the value properly.

If any unexplained malfunctions occur other than the above mentioned, make inquiries at our agency
or the shop where you purchased the unit.

Summary of Contents for Obsolete CF1M

Page 1: ...xander Wiegand Straße 30 63911 Klingenberg Germany Phone 49 93 72 132 0 Fax 49 93 72 132 406 E Mail info wika de www wika de Temperature Indicating Controller Model CF1M WIKA Operating Instructions CF1M V1 1 03 2005 Operating Instructions ...

Page 2: ...rm output open collector R Relay S Logic level DC 0 12 V for solid state relay Control output A Analogue current signal 4 20 mA Input M Multi function input input configuration setable H AC 100 240 V 50 60 Hz Power supply L AC DC 24 V B Factory adjustment Instrument configuration To customers specification CR5 Serial communication RS 485 W10 Heater burnout alarm for 1 phase max 5 A W11 Heater burn...

Page 3: ...ting value MV is being displayed 5 Control output The green LED lights up when the control output is ON indicator 6 Event output The red LED lights up when the Temperature alarm Loop break alarm or indicator Heater burnout alarm is ON 7 Auto tuning The red LED blinks while the Auto tuning or Auto reset is being performed action indicator 3 Operation PV SV display indicates the characters of the se...

Page 4: ...put low limit setting Proportional cycle setting Sensor correction setting Output ON OFF hysteresis setting Temperature alarm setting Instrument number setting Event output function selection Heater burnout alarm output setting Transfer rate setting Temperature alarm action selection Loop break alarm time setting Temperature alarm energized deenergized selection Loop break alarm action span settin...

Page 5: ...alue to 0 disables the function With PD action I 0 auto reset can be performed 0 to 3600 seconds 200s Derivative time setting Sets the derivative time of control output Setting the value to 0 disables the function 0 to 3600 seconds 50s Proportional cycle setting Sets the proportional cycle value This setting item is not available when ON OFF action or current output type is selected 1 to 120 secon...

Page 6: ...an Low limit alarm w standby Input range span to input range span 199 9 to input range span High Low limits w standby 0 to input range span 0 0 to input range span Hi Lo limit range w standby 0 to input range span 0 0 to input range span Process high alarm with standby Input range minimum to input range maximum Input range minimum to input range maximum Process low alarm with standby Input range m...

Page 7: ...osen from 5 types of thermocouple and 4 types of RTD Multi range input type K 0 to 1370 C J 0 to 1000 C PL 0 to 1390 C N 0 to 1300 C E 0 to 800 C Pt100 199 9 to 850 0 C JPt100 199 9 to 500 0 C Pt100 200 to 850 C JPt100 200 to 500 C K 0 to 2500 F J 0 to 1800 F PL 0 to 2500 F N 0 to 2300 F E 0 to 1500 F Pt100 199 9 to 999 9 F JPt100 199 9 to 900 0 F Pt100 300 to 1500 F JPt100 300 to 900 F K PV filte...

Page 8: ... item is not available if Temperature alarm output is not selected in Event output function selection nor if No alarm is selected in Temperature alarm action selection Energized Deenergized Energized Temperature alarm hysteresis setting Sets hysteresis value for temperature alarm This setting item is not available if Temperature alarm output is not selected in Event output function selection nor i...

Page 9: ...ting value has reached 0 or output low limit value if the process variable PV has not fallen at least as low as the value of the span within the time it takes to assess the loop break alarm the alarm will also be activated When the control action is Direct Cooling the alarm acts conversely Energized Deenergized When the status of temperature alarm action is selected energized event output between ...

Page 10: ...sor is indicated on the PV SV display Refer to table 3 1 1 and 3 1 2 During this time all outputs and LED indicators are in their OFF status After that the PV SV display indicates actual temperature If SV display is selected in PV SV display change the setting value will be indicated In the status the Control output OFF function is working it indicates on the PV SV display 2 Input the setting valu...

Page 11: ...6 Action explanations 6 1 Standard action drawing Non contact voltage output Indicator OUT Green ON OFF ON OFF 12Vdc Heating reverse action Cooling direct action Proportional band Proportional band Action Setting Setting Cycle action according to deviation Changes continuously according to deviation Control action Current output Lit Unlit Unlit Lit part Acts ON or OFF Relay contact output 12 0Vdc ...

Page 12: ...dicator OUT Green Current output Lit Unlit Lit Unlit part Acts ON or OFF Non contact voltage output Relay contact output Setting Control action Action Heating reverse action Cooling direct action Hysteresis Hysteresis Setting 12Vdc 4mAdc 0Vdc 20mAdc 12Vdc 0Vdc 4mAdc 20mAdc 4 3 3 3 3 3 3 4 4 4 4 4 4 3 3 4 3 4 3 4 4 4 3 3 ...

Page 13: ...tor Output Indicator Lit Lit Lit Unlit Unlit Unlit Unlit Lit Alarm action Alarm action Unlit Process low alarm action High limit alarm with standby High Low limits alarm with standby part Acts ON or OFF part The standby functions 11 12 12 11 11 12 11 12 11 12 11 12 11 12 12 11 11 12 12 11 12 11 11 12 11 12 11 12 11 12 12 11 12 11 11 12 11 12 11 12 11 12 ON OFF ON OFF ON OFF Alarm action Output Ind...

Page 14: ...the setting value h When the control is stable Fluctuation is given at the setting value ON OFF Unlit Lit Setting Small Large Load current 11 12 11 12 Temperature AT AT Auto tuning starting point PID parameter measuring PID parameter calculated point Controlling action is performed with the parameters set by auto tuning Setting value Time 1 2 3 3 2 1 Temperature 20 lower than the setting value F C...

Page 15: ...that does not change suddenly 4 An ambient non condensing humidity of 35 to 85 RH or less 5 The controller away from large capacity electromagnetic switches or cables through which large current is flowing 6 No water oil or chemicals or where the vapors of these substances can come into direct contact with the unit 8 2 External dimension drawing Fig 8 2 1 Packing B Mounting frame Terminal cover 48...

Page 16: ...CT current transformer dimension drawing CTL 6 S 5A 10A 20A CTL 12 S36 10L1 50A 8 5 Mounting Mounting panel thickness is from 1 to 10mm Insert the CF1M from the front of the panel Insert the mounting frame as shown in Fig 8 5 1 until the four tips of the frame touch the front panel Fig 8 5 1 60 40 45 0 6 0 22 2 0 3 0 ...

Page 17: ...s of this controller Use a 3 wire system of RTD according to the input specifications of this controller This controller has no built in power switch nor fuse It is necessary to install them manually IEC approved 100Vac 5A 220Vac 5A in the circuit near the external controller In the case of 24Vdc do not confuse the polarity With the relay contact output type use an external auxiliary electromagnet...

Page 18: ...aling range K 0 to 1370 C 0 to 2500 F J 0 to 1000 C 0 to 1800 F E 0 to 800 C 0 to 1500 F PL 0 to 1390 C 0 to 2500 F N 0 to 1300 C 0 to 2300 F Pt100 199 9 to 850 0 C 199 9 to 999 9 F 200 to 850 C 300 to 1500 F JPt100 199 9 to 500 0 C 199 9 to 900 0 F 200 to 500 C 300 to 900 F Input sampling period 0 25 seconds Input Thermocouple K J E PL N External resistance 100 Ω or less When input burnout Upscal...

Page 19: ...e does not change at a rate higher than the setting span within the setting time Detects Heater burnout Sensor burnout and Abnormality at operation end Output Open collector Control capacity 24Vdc 0 1A maximum Control action PID action with auto tuning function PD action with auto reset function When I value is set to 0 P action with auto reset function When I and D values are set to 0 ON OFF acti...

Page 20: ... cold junction temperature compensating function Input burnout indicating function upscale downscale Accessories Mounting frame 1 piece Instruction manual 1 copy Terminal cover 1 piece When option KAB is applied Current transformer 1 piece CTL 6 S When option W10 W11 or W12 is applied CTL 12 S36 10L1 When option W15 is applied 8 2 Optional functions Serial communication Option code CR5 When this o...

Page 21: ...led refer to the following items after checking the power and the wiring Indication Phenomenon Presumed cause and the action If PV SV display is indicating Control output OFF function is working Press the OUT OFF key for approx 1s to release the function If is blinking on the PV SV display Thermocouple or RTD is burnt out In the case of Thermocouple If the input terminal of the instrument is conne...

Page 22: ... may be set at the point the value does not change Set it again by Auxiliary function setting mode 1 Control Phenomenon Presumed cause and the action If process variable temperature does not rise Thermocouple or RTD is burnt out Lead wire of thermocouple or RTD is not securely mounted to the instrument terminal confirm the connection of the output is securely carried out If the main output remains...

Reviews: