9
WIKA operating instructions pressure transmitter, model S-11
GB
14043046.01 06/2012 GB/D/F/E
3. Specifications
3. Specifications
3.1 Measuring ranges
Relative pressure
bar Measuring range 0 ... 0.1
0 ... 0.16
0 ... 0.25
0 ... 0.4
0 ... 0.6
0 ... 1
0 ... 1.6
Overpressure limit 1
1.5
2
2
4
5
10
Burst pressure
2
2
2.4
2.4
4.8
6
12
Measuring range 0 ... 2.5
0 ... 4
0 ... 6
0 ... 10
0 ... 16
0 ... 25
0 ... 40
Overpressure limit 10
17
35
35
80
50
80
Burst pressure
12
20.5
42
42
96
96
400
Measuring range 0 ... 60
0 ... 100
0 ... 160
0 ... 250
0 ... 400
0 ... 600
Overpressure limit 120
200
320
500
800
1,200
Burst pressure
550
600
600
600
1,600
1,600
Absolute pressure
bar Measuring range
0 ... 0.25
0 ... 0.4
0 ... 0.6
0 ... 1
0 ... 1.6
0 ... 2.5
0 ... 4
Overpressure limit
2
2
4
5
10
10
17
Burst pressure
2.4
2.4
4.8
6
12
12
20.5
Measuring range
0 ... 6
0 ... 10
0 ... 16
Overpressure limit
35
35
80
Burst pressure
42
42
96
Vacuum and +/- measuring range
bar Measuring range
-0.1 ... 0
-0.16 ... 0
-0.25 ... 0
-0.4 ... 0
-0.6 ... 0
-1 ... 0
-1 ... +0.6
Overpressure limit
1
1.5
2
2
4
5
10
Burst pressure
2
2
2.4
2.4
4.8
6
12
Measuring range
-1 ... +1.5
-1 ... +3
-1 ... +5
-1 ... +9
-1 ... +15
-1 ... +24
Overpressure limit
10
17
35
35
80
50
Burst pressure
12
20.5
42
42
96
96
Summary of Contents for S-11
Page 76: ...76 WIKA Mode d emploi transmetteur de pression type S 11 F 14043046 01 06 2012 GB D F E ...
Page 101: ......
Page 102: ......