10 Installation and maintenance record 

 

Please complete carefully. 
The installation and maintenance record is part of the warranty and will be requested in case of complaints with the corresponding invoice. 
 

  Installation

  Maintenance

Contact Data

Name

Company

Street No

ZIP / Town

Phone

Mobile

E-mail

Date

Installer

Brand

(designation)

Type 

(serial no.)

Material

Yes    No

Anode type

Vol.

l

m

2

       

Vol.

l

m

2

       

   I        II       III

Vol.

l

Max. 

temperature

Difference in 

temperature

Hystere = 
Delta t off

°C

K

K

°C

K

K

°C

K

K

°C

K

K

°C

°C

Target :         l/min Actual:            l/min

System working pressure at

°C

bar

Target :           bar

Actual :             bar

Visual control

Brand / type

Actual value

  rinsed

Filling capacity

Liter ph-value

  filtered

Mixing ratio

% antifreeze upto

  purged

yes / no

yes / no

yes / no

  with AIR-Stop in the solar circuit

  wiht quick vent valve at collectors

Primary pressure exp. vessel

°C

Type

Cooling function * from

 colour unchanged     

 brown     

  black     

  cloudy

Flow rate

Ø        ,         m

System - settings

(Controller setting = *)

Consumer 1* = e.g. DHW

Consumer 2* = e.g. buffer tank 1

S

y

s

te

m

Minimum value

7

-25°C

Insulation

Thickness    mm

Solar liquid

Consumer 3* = e.g. buffer tank 2

Consumer 4* = e.g. swimming pool

Max. collector temperature*

Backup heat target temperature*

Material overview

Characteristics

(dimensions)

Collector

Pipeline (single)

Tank 2

Controller

DHW system

Heat exchanger

Expansion vessel

Installer

First installation

Last maintenance

Solar pump

Level

Final customer

Tank 1

For stainless steel tank(s): 
Additional corrosion protection needed? 
(please consider indications of the local 
water supplier)

In case of quick vent valve, please add drawing.

How is the solar ventilation system designed?

Space heating

DHW-mixing valve

Number of collectors

 S / SE / SW / E / W      ca.          Grad

Mounting type

OR / IR / FR / horizontal / vertical

single row / double row / parallel / series

Hydr. connection

Orientation/Pitch

 

 

 

Summary of Contents for Wikosun 2010

Page 1: ...e covered if the installation instructions are followed Warranty does not cover any damages caused by non observance of this manual The correct functioning is only guaranteed if the installation instr...

Page 2: ...Wikosun 2010 2510 Profile rails aluminum Z clamp Collector support bracket Parallel compression fitting 18mm Compression X fitting 18x18x12 x3 4 FD incl air screw and sensor pocket Insulation on site...

Page 3: ...6 washers ST BFS BL 2 clamps for rolled steel joist 2 screws M8 2 nuts M8 ST BFS ST 2 stair bolts M10 2 ears 6 nuts 2 seals ST BFS T 2 roof hooks profiled sheeting ST BFS W 2 roof hooks corrugated sh...

Page 4: ...s 5 mm 1 Flat section aluminum 40x5 mm l 1710 mm s 5 mm 7 Hex head screws stainless steel M8 x 20 mm 7 Hex nuts stainless steel M8 7 Lock washers M8 Chart 4 Fastening sets flat roof mounting horizont...

Page 5: ...with reference to DIN 1055 100 DIN 1055 4 and DIN 1055 5 Determine the values of local snow loads according to country specific data Determine the values of local wind loads according to country speci...

Page 6: ...mensionally mediated according to the number of collectors The distances between the upper and lower profile rail are as follows see fig 4 On roof mounting vertical 1500 1600 mm WIKOSUN 2010 1800 1900...

Page 7: ...ms Smaller rafters should be doubled or trebled in width at the point where brackets are to be fixed to them see fig 6 If a foil under the roof tiles exist and is harmed during installation the openin...

Page 8: ...al installation 0 5m 200 kg 300 kg 5 10 m 250 kg 350 kg 10 20 m 300 kg 400 kg 20 m Calculation necessary Chart 8 Loading per collector 3 3 1 1 Installation of the mounting frame on mass elements e g c...

Page 9: ...ulated and measured For roof angles smaller than 60 the vertical angle section must be cut 25mm above the hole Install the base of the frame the cross bars and the back bars and connect the angle sect...

Page 10: ...Position the collectors and fix them carefully The collectors are connected with each other by using the corresponding parallel compression fittings Hand tighten the bolts and protect the connecting...

Page 11: ...shions 3 9 Hydraulic pressure test After a successful installation rinse the entire collector circulation with water Before commissioning the collector circulation must be checked with a water pressur...

Page 12: ...450 25 18 9 540 40 22 10 5 630 40 22 12 720 50 22 13 5 810 50 28 15 900 80 Valid for parallel collector connection In the case of series connection of the same collector arrays the flow rate is halve...

Page 13: ...ool Absorber Material Aluminium plate on copper Aluminium plate on copper Absorber coating TINOX ENERGY Alanod Mirotherm TINOX ENERGY Alanod Mirotherm Pressure loss 50 l h 49 Pa collector 54 Pa collec...

Page 14: ...minated Switch on again your solar heating system Please never vent at sunshine or running pump Please do not undertake an additional venting process If the system s working pressure drops later on or...

Page 15: ...no atmospheric oxygen in the system It must be ensured that the circulating pump is suitable for operation with antifreeze agents Before being filled the system should be flushed with water and the ti...

Page 16: ...he local authority in charge Cleaning clean with liquid binding material sand kieselguhr acid binder or universal binder Recycle contaminated material separately Keep the concentrate in a cool and dry...

Page 17: ...hidden defects immediately after emerging In case of hidden defects it is only valid for the warranty exceeding the legal warranty period if the collectors are changed or maintained by non spezialise...

Page 18: ...ick vent valve at collectors Primary pressure exp vessel C Type Cooling function from colour unchanged brown black cloudy Flow rate m System settings Controller setting Consumer 1 e g DHW Consumer 2 e...

Page 19: ...ollector fastening is stable User has been instructed Maintenance contract Operation of pumps checked Temperature sensores indicate realistic values Collector interior is not fogged Collector is clean...

Reviews: