INSTALLATION INSTRUCTIONS
II22
Style may vary
Style may vary
Strain
relief
220 Volt
power
cable
Terminal
block
Installation
Leveling
1 Position the dispenser on the counter top. Level it left
to right and front to back by turning the bottom of the
legs.
Connect the Water Supply
2 Flush the water supply line prior to installation to
QVSHFBJSBOEEFCSJTGSPNUIFXBUFSmMUFSBOEUVCJOH
3
$POOFDUUIFXBUFSTVQQMZMJOFUPUIFnBSFmUUJOHPOUIF
back of the unit. Leave the water supply valve closed
until power is connected.
Connect the Wiring - Dual Voltage Units to be Operated
220-240 Volts Only
4 Remove the top cover and the left side panel to
expose the terminal block.
5 Disconnect and cap the jumper wire between the “C”
and “N” terminals on the terminal block.
6 Loosen the strain relief on the back panel.
7 Disconnect the 120 Volt power cable from the terminal
block and pull the cable out through the back.
8 Feed the end of the 220-240 Volt power cable through
the strain relief, into the unit.
9 Connect the wires on the power cable to the terminal
block inside.
10 Tighten the strain relief and replace the side and top
panels.
11 Connect the power cable wires to the terminals in the
junction box. See the
ELECTRICAL SCHEMATIC
for
the power supply requirements.
WARNING:
Use the leveling legs to level the
dispenser only. Do not use them to adjust
dispenser height. Do not extend them higher
than necessary.
WARNING:
Turn off power to the junction box at
the circuit breaker panel before connecting the
power cable to the dispenser. Lock out and tag
the circuit breaker.
1$(5&913*/45"--"5*0/*/4536$5*0/4ø
100318A
Back of unit
d
c