P E R F O R M A N C E
WILDEN PUMP & ENGINEERING, LLC
12
PX8 HS
Performance
SET
TING 4 PERFORMANCE CUR
VE
EMS CUR
VE
PX8 S
ANIFL
O HS FULL S
TROKE RUBBER-FITTED
TECHNIC
AL D
A
T
A
Height
. . . . . . . . . . . . . . . . . . . . . . . . .
1008 mm (39.7”)
Width
. . . . . . . . . . . . . . . . . . . . . . . . . . .
460 mm (18.1”)
Depth
. . . . . . . . . . . . . . . . . . . . . . . . . . .
498 mm (19.6”)
Ship W
eight
. . . . . . . . . . . . . . . . . . . . .
49 kg (109 lbs.)
Air Inlet
. . . . . . . . . . . . . . . . . . . . . . . . . . .
19 mm (3/4”)
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51 mm (2”)
Outlet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51 mm (2”)
Suction Lift
. . . . . . . . . . . . . . . . . . . . .
5.3 m Dry (17.3’)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.0 m W
et (29.5’)
Disp. Per Stroke
. . . . . . . . . . . . . . . . . .
1.1 l (0.28 gal.)
1
Max. Flow Rate
. . . . . . . . . . . . . . . .
579 lpm (153 gpm)
Max. Size Solids
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mushroom V
alve
. . . . . . . . . . . . . . . . .
6.4 mm (1/4”)
Ball V
alve
. . . . . . . . . . . . . . . . . . . . . . .
12.7 mm (1/2”)
Flap V
alve (compressible solids)
.
47.5 mm (1-7/8”)
Surface Finish
. . . . . . . . . . . . . . . .
Ra 0.8 µm (32 µ-in)
1
Displacement per stroke was calculated at 4.8 bar (70 psig)
air inlet pressure against a 2 bar (30 psig) head pressure.
The Effi
ciency Management System (EMS)
can be used to optimize the performance of
your Wilden pump for specifi
c applications.
The pump is delivered with the EMS adjusted
to setting 4, which allows maximum fl
ow
.
The EMS curve allows the pump user to deter
-
mine fl
ow and air consumption at each EMS
setting. For any EMS setting and discharge
pressure, the “X factor” is used as a multi-
plier with the original values from the setting
4 performance curve to calculate the actual
fl ow and air consumption values for that spe-
cifi
c EMS setting. Note: you can interpolate
between the setting curves for operation at
intermediate EMS settings
EXAMPLE
A PX8 Sanifl
o HS, full stroke Rubber
-fi
tted pump operating at EMS
setting 4, achieved a fl
ow rate of 348 lpm (92 gpm) using 119 Nm
3
/h
(70 scfm) of air when run at 5.5 bar (80 psig) air inlet pressure and 2.1
bar (30 psig) discharge pressure (See dot on performance curve).
The end user did not require that much fl
ow and wanted to reduce
air consumption at his facility
. He determined that EMS setting 2
would meet his needs. At 2.1 bar (30 psig) discharge pressure and
EMS setting 2, the fl
ow “X factor” is 0.74 and the air “X factor” is
0.48 (see dots on EMS curve).
Multiplying the original setting 4 values by the “X factors” provides
the setting 2 fl
ow rate of 258 lpm (68 gpm) and an air consumption
of 57 Nm
3
/h (34 scfm). The fl
ow rate was reduced by 26% while
the air consumption was reduced by 52%, thus providing increased
effi
ciency
.
For a detailed example for how to set your EMS, see beginning of
performance curve section.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.
Flow rates indicated on chart were determined by pumping water with a vertically mounted, center ported ball check confi
guratio
n.
When alternate check valve options are used, multiply fl
ow rate by appropriate factor: Flap check valve = 83%. For optimum life
and
performance, pumps should be specifi
ed so that daily operation parameters fall in the center of the pump performance curve.