WIL-12310-E-04
25
WILDEN PUMP & ENGINEERING, LLC
P U M P D I S A S S E M B L Y
Step 4
Next, remove the clamp bands that
secure the ball valve housing to the
liquid chamber.
Step 5A
Next, remove the ball valve housing,
valve ball and gasket.
Step 5B
If your pump is fi
tted with a
mushroom valve, remove the
mushroom valve housing,
mushroom valve and gasket.
Step 6
Loosen the wing nut and remove
the inlet manifold clamp bands.
Step 7
Next, remove the clamp bands that
secure the ball valve housing to the
liquid chamber.
Step 8
Next, remove the ball valve
housing, valve ball and gasket from
liquid chamber. To ensure proper
alignment during reassembly of
manifold/liquid chamber interface,
turn off-set portion of valve
housing to the left or to the right.
This procedure works for the inlet
manifold and discharge manifold
connections.