Accupoint Positioners
3-46
PM-01010-REV 2
May 2022
3.4.3.5 Setting Limit Stops with the Keyboard
To set the electronic limit stops with the keyboard:
1. Drive the positioner to the desired electronic limit stop.
2. Press [Set].
3. Press [N] where “N” represents the number which corresponds to the preset being
adjusted. Reference Table 3-2 to determine which number to use to change each
electronic limit stop.
Table 3-2 Limit Stop Presets
Set Preset [N]
Function
80
Stores New Pan Left (Counterclockwise) Limit
81
Stores New Pan Right (Clockwise) Limit
82
Stores New Up Limit
83
Stores New Down Limit
4. Press [Pre]. The electronic limit has been adjusted and the positioner will no longer
move past that point.
5. Test to ensure electronic limit stop has been properly set.
Note that it is possible to set the electronic limit stops such that the positioner cannot move
(e.g; setting the clockwise and counterclockwise limits to the same spot). If this happens,
clear the electronic limit stops and reset electronic limit stops to the desired location.
3.4.3.6 Clear Limit Stops with the Keyboard
To clear the electronic limit stops with the keyboard:
1. Press [Set].
2. Press [N] where “N” represents the number which corresponds to the preset being
cleared. Reference Table 3-3 to determine which number to use to change each
electronic limit stop.
3. Press [Pre]. The electronic limit stops have been cleared.
Ensure new limit stop is set.
Summary of Contents for ACCUPOINT AP-50
Page 2: ......