background image

 

Shenzhen Bayite Technology Co., Ltd 

Email: service@bayite.com 

 

Thank you for choosing this WILLHI Digital Temperature 

Controller! Please read through this manual for trouble free 

operation. 

 

 

Features:  

  Turn device on and off at desired temperatures.  

  Settings are saved even when powered off. 

  Temperature calibration correction  

  High and low temperature alarm 

  Built in time delay feature to protect output device from excessive 

on/off toggling. 

  Auto shut off timer(disabled by default) 

 

 
Technical Specifications:

 

  Max Load: 10 amps (1100 watts @110 volts) 

  Power supply: AC 110V, 50/60Hz  

  Probe measurement range: -58°F ~ 230°F / -50°C ~ 110°C 

  Temperature Accuracy: 0.1 

  Working temperature for the controller: -40°F~176°F / -40°C ~ 80°C 

  Unit power consumption: < 3W

 

  Plug type: NEMA 5-15 AC plug 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for WH1436A

Page 1: ...ut when a short or overloading is detected If the fuse reset pops out the short or overloading condition must be fixed before the button will stay pushed in Do not manually hold the button in as this will create a dangerous condition The button needs at least 2cm 0 8 inches clearance to pop out Be sure it s not blocked Search WH1436A INSTRUCTION for the video on YouTube ...

Page 2: ...unit with a damaged power cord is a fire and electrical shock hazard Should this unit be dropped or damaged turn the power switch off remove the power plug from the AC outlet If you continue using the unit without heeding this instruction fire or electrical shock may result If you notice any abnormality such as smoke odor or noise or if a foreign object or liquid gets inside the unit turn it off i...

Page 3: ...red off Temperature calibration correction High and low temperature alarm Built in time delay feature to protect output device from excessive on off toggling Auto shut off timer disabled by default Technical Specifications Max Load 10 amps 1100 watts 110 volts Power supply AC 110V 50 60Hz Probe measurement range 58 F 230 F 50 C 110 C Temperature Accuracy 0 1 Working temperature for the controller ...

Page 4: ...led if you specify a value for AL or AH Press any button to silence the alarm when it sounds Unplug the unit briefly to enable the alarm function again Quick Start Set two parameters the on and off temperatures These are ON and OFF respectively in the settings menu Set ON to the desired temperature the unit should supply output power and OFF to the desired temperature the unit should shut off outp...

Page 5: ...t off the device plugged in the controller rather than the controller itself This parameter only appears after you enable timer in advanced menu by setting dL ON Trouble Shooting A The output device won t power on Check that the controller and the output device are securely plugged in and the value for power on temperature ON is set correctly B The controller displays EEE while beeping The probe i...

Page 6: ...dure 1 OFF timer starts counting down once target temp is reached Refer to Setup procedure 2 Setup procedure 1 Enter advanced menu set dL ON set U ON Press POWER once to quit advanced setting enter main menu to set related parameter and set AT Press POWER once to quit setting now the screen displays current temp and OFF alternately Press POWER once again to start the process You ll hear a long bee...

Reviews: