PLA DL210NET Digi-Loop™ DSP Induction Loop Amplifier
31
STATUS BOX AND AMPLIFIER STATUS WINDOW
The status box shows loop status at a glance. For more detail, open the Amplifier Status Window.
Figure O: Amplifier Status Window
A483
Status Box. Click inside
the box to open the
Amplifier Status Window.
CALIBRATION WINDOW
The amplifier must be calibrated to the loop(s) before the VU meters will be accurate. For the complete procedure on calibrating the
amplifier, please refer to the section “Setup and Calibration Procedure (using a laptop or windows tablet)”. When calibrating a Phased
Array, after Loop A has been calibrated with the field strength meter, switch to Loop B, and adjust the Offset for Loop B until the
Average Current for Loop B matches the average current for Loop A (Figure P).
Figure P: Calibration Window (Phased-Array Mode shown)
Average current
delivered to
Loop A.
A484
Click on this button
to switch from
Loop A to Loop B to
Loop A+B.
Using the
current in Loop A
as a reference,
When finished,
the current for Loop A
should be close to
the current for Loop B.
adjust the offset
for the current in Loop B
until Loop B is close to Loop A.