background image

 

Replacements Parts 

 

 

 

18 

 

REPLACEMENT PARTS FOR MODELS: 4505621A; 4505622A; 6005621A; 6005622A 

 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
For part illustration, see page 17. 
Note: Screws and bolts are standard hardware items, available locally. 

 

 

Ref. 

Number

 

Description

 

PART NO. FOR MODEL 

4505621A

 

4505622A

 

6005621A

 

6005622A

 

GRILLE,  FLOOR 

P322428 

P322428 

P322429 

P322429 

INNER, LINER  ASSY 

4B0041 

4B0041 

4B0042 

4B0042 

L.H.  SECONDARY 

CHAMBER 

4B0056-1 

4B0056-1 

4B0057-1 

4B0057-1 

COMBUSTION  CHAMBER 

4B0046 

4B0046 

4B0047 

4B0047 

R.H. SECONDARY 

CHAMBER 

4B0056-2 

4B0056-2 

4B0057-2 

4B0057-2 

OUTER SHIELD ASSY 

4B0036 

4B0036 

4B0069 

4B0069 

PEEP HOLE COVER ASSY 

12B40 

12B40 

12B40 

12B40 

IGNITOR 

P285500 

P285500 

P285500 

P285500 

SWITCH, LIMIT 

P323031 

P323031 

P323031 

P323031 

10 

KEY, CONTROL 

P322445 

P322445 

P322445 

P322445 

11 

ROD, CONTROL 

4A0037 

4A0037 

4A0037 

4A0037 

12 

ROD, LIGHTER 

P322431 

P322431 

P322431 

P322431 

13 

WIRE, THERMOSTAT 

P710000 

P710000 

P710000 

P710000 

14 

THERMOSTAT 

P322016 

P322016 

P322016 

P322016 

15 

CONTROL VALVE  NAT. 

P323177 

P323177 

CONTROL VALVE L.P.G. 

P323178 

P323178 

16 

BRACKET, VALVE 

4B0087 

4B0087 

4B0087 

4B0087 

17 

MANIFOLD ASSY 

4A0042 

4A0042 

4A0042 

4A0042 

18 

PILOT NAT. 

P501617 

P501617 

PILOT L.P.G. 

P501618 

P501618 

19 

SHIELD, BURNER 

4B0014 

4B0014 

4B0010 

4B0010 

20 

BURNER 

P323674 

P323674 

P323673 

P323376 

21 

GASKET, FLUE  OUTLET 

P322439 

P322439 

P322439 

P322439 

22 

DRAFTHOOD COLLAR 

ASSY 

4B0072 

4B0072 

4B0072 

4B0072 

23 

DRAFTHOOD ASSY 

4B0026 

4B0026 

4B0026 

4B0026 

24 

ENVELOPE ASSEMBLY 

4A0024 

4A0024 

4A0024 

4A0024 

Summary of Contents for 4505621A

Page 1: ...ion adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or for additional information consult a qualified installer service agency or t...

Page 2: ...do not involve defective workmanship or materials DUTIES OF THE CONSUMER 1 The heating equipment must be installed by a qualified installer and operated in accordance with the installation and homeown...

Page 3: ...tallation 10 12 Operating Your Furnace 13 15 Start Up Procedure 13 Operating Instructions 14 15 How to Care for Your Furnace 16 Gas Conversion Kits 16 Repair Parts Parts Lists 17 18 Troubleshooting Ch...

Page 4: ...directly to the outdoors so that harmful gases will not collect inside the building Follow the venting instructions for your type of installation exactly Use only the type and size of vent pipe and fi...

Page 5: ...the standards set by the American National Standards Institute and the design has been certified by CSA as conforming to these standards Care has been taken to assure that your furnace will operate sa...

Page 6: ...openings supplying this furnace are kept clear at all times Continued safe and satisfactory performance of this furnace requires but is not limited to periodic examination of the vent system pilot fl...

Page 7: ...gh away from the furnace to prevent it from being heated directly by the furnace Select a location in the area most frequently used or best situated to control the temperature of the entire house Avoi...

Page 8: ...t is practical but if it is necessary to use one vent for two furnaces be sure the vent or chimney has an interior liner at least 6 inches in diameter 7 If two furnaces are connected to a chimney or v...

Page 9: ...atural gas and 10 0 inches for L P Gas If the furnace is equipped for L P Gas the gas tank must be provided with a regulator which will reduce the line pressure to the furnace to between 11 and 13 inc...

Page 10: ...nces 8 Remove the grille from the furnace 9 Lower the furnace into the floor opening until the flanges on the furnace cabinet rest on the floor 10 Fasten the furnace in place by driving nails through...

Page 11: ...ure 12 If the flame is not pulled into the draft hood the chimney is not providing sufficient draft This can allow hazardous gases to escape the vent system Find and correct the causes of this malfunc...

Page 12: ...Installing Your Furnace 12 FIGURE 9 Flame Adjustment FIGURE 10 Installation of Draft Hood FIGURE 11 Flame Pattern FIGURE 12 Performance Check...

Page 13: ...0 to 12 inches of water should be used for this measurement The manifold pressure must be measured with the burner and pilot operating Any major changes in flow must be made by changing the size of th...

Page 14: ...4 Wait five 5 minutes to clear out any gas then smell for gas including near the floor IF YOU SMELL GAS STOP Follow B In the safety information above If you don t smell gas go to the next step 5 Find...

Page 15: ...mit control if the furnace is in an area occupied by children or elderly persons who could fall on the furnace and be burned Burner Flame Characteristics Start the furnace and let it operate for at le...

Page 16: ...of the cabinet about one inch and then lift it out of the cabinet WARNING DANGER OF BODILY INJURY OR DEATH DO NOT OPERATE THE FURNACE WITH A BROKEN OR MISSING PILOT OBSERVATION DOOR If the control and...

Page 17: ...Replacement Parts Accessories 17 WILLIAMS GAS FIRED FLOOR FURNACE REPLACEMENT PARTS FOR 450 600 MODEL SERIES FLOOR FURNACE FOR PARTS LISTING SEE PAGE 18 USE ONLY MANUFACTURERS AUTHORIZED PARTS...

Page 18: ...NITOR P285500 P285500 P285500 P285500 9 SWITCH LIMIT P323031 P323031 P323031 P323031 10 KEY CONTROL P322445 P322445 P322445 P322445 11 ROD CONTROL 4A0037 4A0037 4A0037 4A0037 12 ROD LIGHTER P322431 P3...

Page 19: ...ow pressure Adjust pressure regulator 6 Failure to ignite A Main gas off Open manual valve B Defect in gas valve Replace C Defective thermostat Replace 7 Burner won t turn off A Poor thermostat locati...

Page 20: ...ctly a fire or explosion may result causing property damage personal injury or loss of life Williams Furnace Company 250 West Laurel Street Colton CA 92324 909 825 0993 FAX 909 824 8009 www wfc fc com...