background image

PLB-112 

Oil Furnaces

 – 

Furnace Manual

 

24

  

11/13 

6.  COMPONENT AND REPLACEMENT PARTS (continued) 

Table 15: Parts List - With variable speed motor ECM 

Item

Part

Description

Comments

1

B03690

HEAT EXCHANGER ASSEMBLY

Heat exchanger only

2

J06L002

SEAL STRIP DIA 1/8" DIA X 25'

3

B03696

FLOOR ASSEMBLY

4

B03709

WIRE CHANNEL, INT

5

B03695-01

LOWER BLOWER DIVIDER ASSEMBLY

Panel, 3 gaskets and baffle included

6

B03719

CENTER BLOWER DIVIDER

7

B03708

SIDE BAFFLE

8

B03694-04

LEFT SIDE PANEL ASSEMBLY

Panel, insulation and baffle included

9

B03714-02

LEFT SIDE PANEL INSULATION

10

B03711-02

LEFT ANGLE FILTER RACK

11

B03710

SIDE FILTER RACK

12

Z04F004

PAPER FILTER 20 X 20 X 1

13

B03697-01

BLOWER DOOR ASSEMBLY

Door, handle and labels included

14

Z99F050

HANDLE, RECESSED BLACK

15

B03577-01

REAR FILTER DOOR ASSEMBLY

16

F07O001

HEX FLANGE NUT 3/8-16NC LAITON

17

B01697

FLUE OUTLET FLANGE, 5" DIA.

18

B01214

GASKET, SMOKE PIPE COVER

19

B03988

TOP REAR PANEL ASSEMBLY

Panel and label included

20

B03718

REMPLACEMENT SOUND TRAP ASSEMBLY

2 sections included

21

B03712

OUTLET PROTECTOR

22

B03705

TOP DIVIDER

23

B03694-03

RIGHT SIDE PANEL ASSEMBLY

Panel, insulation and baffle included

24

B03714-01

RIGHT SIDE PANEL INSULATION

25

B03711-01

RIGHT ANGLE FILTER RACK

26

B03553-01

ELECTRICAL BOX SPACER

27

B03534-01

ELECTRICAL BOX

28

R02R003

HIGH LIMIT L195-30F, 1.75 in.

29

B03550-01

ELECTRICAL BOX COVER

Panel only

30

F06F015

ZINC WASHER 1 7/16"

31

Z99F061

SIGHT GLASS FOR HEAT EXCHANGER

32

B03587

CLEAN OUT ASSEMBLY

Item #37 included

33

B03574-03

PROTECTION COVER ASSEMBLY

Cover and labels included

34

B03428

GASKET, SMOKE OUTLET 

35

F07F011

HEX NUT 3/8-16NC ZINC

36

B03567

BAFFLE

One baffle uncluded

37

B03596-01

BURNER WIRE CHANEL

38

B03554-01

WIRE CHANEL

39

L04I010

STRAIN REL. BUSHING 

40

B03573-01

FRONT PANEL ASSEMBLY

Panel and insulation uncluded

41

B03590

FRONT PANEL INSULATION

42

B03555

THERMO DISK PROTECTOR

43

B03465

ELECTRICAL KIT (BOARD)                    

44

R99G003

ELECTRONIC BOARD #1168

45

L01F009

TRANSFORMER  120-24Volts, 40VA

46

B03243-01

ELECTRIC BLOWER KIT                     

47

B03242-01

ELECTRONIC BLOWER KIT

48

B03812-02

MOTOR 3/4 HP ECM

49

B01889

MOTOR MOUNT ASSEMBLY

Band, legs, nut & bolts included

50

B03713

BLOWER SUPPORT

51

B03720-06

BLOWER 120-9T DD 0.5 PP

Housing, wheel and label included

52

B03717-02

REPLACEMENT BLOWER ASSEMBLY

Blower and motor included

53

L01G009

CONTROL CARD FUSE - 3 AMPS

VENT TERMINAL KIT 4''

For sealed combustion

4" INSULATED FLEX VENT 10ft

For sealed combustion

4" INSULATED FLEX VENT 15ft

For sealed combustion

4" INSULATED FLEX VENT 20ft

For sealed combustion 

IFV-420

ACCESSORIES

VTK-54
IFV-410
IFV-415

 

B50129A 

Summary of Contents for PLB-112 LOW-BOY

Page 1: ...y could result in severe personal injury death or substantial property damage When calling or writing about the furnace Please indicate furnace model number and serial number from rating label You may...

Page 2: ...bows 20 Always connect and seal a return air duct to the furnace unless the furnace is located in a large space such as an unpartitioned basement Route the return air duct to an adjacent room if no re...

Page 3: ...to a hazardous electrical condition and to premature failure of the equipment The minimum clearances from combustible material for each of the positions are specified in Table 1 If the furnace is ins...

Page 4: ...r to the burner manufacturer s instructions Also the burner must be installed always in the same way independently of the furnace orientation 1 Position the mounting gasket between the mounting flange...

Page 5: ...where the draft is either high or variable due to external conditions Follow the instructions provided with the regulator 1 5 4 Side wall Venting The heating unit is approved for side wall venting Th...

Page 6: ...xposure to the following substances a Permanent wave chemicals for hair b Chlorinated waxes and cleaners c Chlorine based swimming pool chemicals d Water softening chemicals e De icing salts or chemic...

Page 7: ...nstalled with a 4 tons air conditioning evaporator coil Heating mode airflow is still 1050 CFM Cooling mode air flow use Equation 3 4 CFM 4 x 400 1600 CFM The larger number is 1600 CFM cooling so the...

Page 8: ...7 6 6 900 14 58 41 31 25 21 19 17 14 12 11 10 9 8 8 7 7 7 1000 16 64 45 34 28 23 20 18 15 13 11 10 9 9 8 8 7 7 1100 16 72 49 38 30 25 22 19 16 14 12 11 10 9 9 8 8 7 1200 16 54 41 33 27 24 21 17 15 13...

Page 9: ...600 12 59 38 28 22 19 16 15 13 700 12 69 44 32 25 21 18 16 15 13 800 14 50 36 29 24 20 18 16 14 900 14 56 41 32 26 22 20 18 15 1000 16 63 45 35 29 24 22 19 17 15 1100 16 69 49 38 31 26 23 21 18 16 120...

Page 10: ...same the RED wire must be moved to UNUSED LEADS on the electronic board and the jumper provided with the BLUE wire must be used between the HEAT and COOL terminals The blower start stop delays can be...

Page 11: ...he blower rail locking screws are well tightened 3 The Blocked Vent Shut Off BVSO is installed according to instructions for chimney venting 4 The oil supply valve is open 5 The burner Reset button is...

Page 12: ...himney installation and 0 05 to 0 17 W C for direct vent installation A high pressure condition may be caused by excessive combustion air due to the air band being too wide open or a lack of flue draf...

Page 13: ...heat exchanger and combustion chamber should be inspected to determine if replacement is required 8 After the cleaning replace the heat exchanger baffles flue collar plate and oil burner 9 Readjust t...

Page 14: ...rough furnace checked not to exceed 85 F and the blower speed adjusted if necessary 19 Was the thermostat heat anticipator set per wiring diagram 20 Was the burner started and tested per burner manual...

Page 15: ...__________ Serial number __________________________________ Date installed ___________________________ Installation instructions have been followed Checkout sequence has been performed Above informati...

Page 16: ...zing Maximum fuse size amps Ship weight pounds PLB 112 DD 55 75 1 x 20 x 20 or 2 x 16 x 20 115 60 1 12 6 15 2 20 195 PLB 112 VS 60 72 1 x 20 x 20 or 2 x 16 x 20 115 60 1 12 2 14 7 15 195 0 25 w c 0 50...

Page 17: ...112 VS Model Input BTU h Firing rate USGPH AFUE Nozzle Delavan Pump pressure PSIG Burner tube insertion length Inch Combustion air adjustment Turbulator Damper 95 200 0 68 86 6 0 60 70A 130 1 2 6 112...

Page 18: ...C 1 OFF 2 ON 3 0 1200 1320 1080 D 1 ON 2 ON 2 5 1000 1100 900 SW4 DELAY DIP switch position HEAT INPUT USGPH PreRun On Delay CFM Level Time ShortRun On Delay CFM Level Time Off Delay CFM Level Time A...

Page 19: ...PLB 112 Oil Furnaces Furnace Manual 11 13 19 5 DIMENSIONS AND RATINGS continued Figure 9 Wiring Diagram 4 Speed Motor PSC...

Page 20: ...PLB 112 Oil Furnaces Furnace Manual 20 11 13 5 DIMENSIONS AND RATINGS continued Figure 10 Wiring Diagram Variable Speed Motor ECM...

Page 21: ...PLB 112 Oil Furnaces Furnace Manual 11 13 21 6 COMPONENT AND REPLACEMENT PARTS Figure 11 Parts List With 4 Speed motor PSC B50128A...

Page 22: ...TER RACK 26 B03553 01 ELECTRICAL BOX SPACER 27 B03549 01 ELECTRICAL BOX 28 R02R003 HIGH LIMIT L195 30F 1 75 in 29 B03550 01 ELECTRICAL BOX COVER Panel only 30 F06F015 ZINC WASHER 1 7 16 31 Z99F061 SIG...

Page 23: ...PLB 112 Oil Furnaces Furnace Manual 11 13 23 6 COMPONENT AND REPLACEMENT PARTS continued Figure 12 Parts List With variable speed motor ECM B50129A...

Page 24: ...ION 25 B03711 01 RIGHT ANGLE FILTER RACK 26 B03553 01 ELECTRICAL BOX SPACER 27 B03534 01 ELECTRICAL BOX 28 R02R003 HIGH LIMIT L195 30F 1 75 in 29 B03550 01 ELECTRICAL BOX COVER Panel only 30 F06F015 Z...

Page 25: ...f the furnace oil burner should shut down on flame failure the burner primary control will lock out Ask your service technician to show you the correct procedure to reset the primary control button NE...

Page 26: ...PLB 112 Oil Furnaces Furnace Manual 26 X40207 Rev B 11 13...