PMP-098
Oil Furnaces
–
Furnace Manual
18
11/13
5.
DIMENSIONS AND RATINGS (continued)
Table 11: Model PMP-098 Burner data
Model
Input
BTU/h
(*)
Firing
rate
USGPH
(*)
AFUE
(***)
Nozzle
(Delavan)
(**)
Pump
pressure
(PSIG)
(*)
Head
Low firing
rate baffle
Burner
tube
insertion
length
(Inch)
Static
disc
ATC
Head/Air
setting
70,000
0.50
85.2%
0.40 - 60A
175
Yes (5880)
4/0
84,000
0.60
85.1%
0.50 - 60A
150
Yes (5880)
8/0
98,000
0.70
83.9%
0.60 - 60B
140
No
5/0
70,000
0.50
85.2% ‡
0.40 - 60A
175
Yes (5880)
4/0
84,000
0.60
85.1% ‡ 0.50 - 60A
150
Yes (5880)
8/0
BECKET BURNER; MODEL AFG (Chimney)
2 - Slot
L2
1 3/4"
PMP-098-DD
PMP-098-VS
3 3/8 U
AFG70MQSS
Model
Input
BTU/h
(*)
Firing
rate
USGPH
(*)
AFUE
(***)
Nozzle
(Delavan)
(**)
Pump
pressure
(PSIG)
(*)
Head
Low firing
rate baffle
Burner
tube
insertion
length
(Inch)
ATC
Head/Air
setting
70,000
0.50
86.1%
0.40 - 60W
155
Yes (32229)
2,0
84,000
0.60
85.4%
0.50 - 60W
145
Yes (32229)
2,5
98,000
0.70
84.5%
0.60 - 60W
135
No
2,5
70,000
0.50
86.1% ‡
0.40 - 60W
155
Yes (32229)
2,0
84,000
0.60
85.4% ‡ 0.50 - 60W
145
Yes (32229)
2,5
PMP-098-VS
NX56LQ
BECKET BURNER; MODEL NX (Chimney or DV)
6 - Slot
LQ
1 3/4"
PMP-098-DD
* INPUT & OUTPUT ADJUSTMENT
- Pump pressure can be adjusted to maintain proper firing rate.
- Increase pump pressure if flue gases temperature are under 400°F.
- Adjust the total flue gas temperature between 400°F and 575°F (330°F and 505°F net approximately)
** Default Installed Nozzle in bold characters
*** AFUE values established after minimum 20 hours of operation.
C US
PMP furnaces are CSA design
certified for installation
on combustible flooring.
‡=