PMP-112 Multiposition
Oil Furnaces
–
Furnace Manual
11/13
17
5
DIMENSIONS AND RATINGS
Table 10: Model PMP112-DD & PMP-112-VS Dimensional data – ALL DIMENSIONS IN INCHES
Width
Depth
Height
Width
Depth
Width
Depth
PMP-112-DD
21 ¾"
25 ¾"
41"
17 ¾"
18 ¾"
23"
19"
5"
PMP-112-VS
21 ¾"
25 ¾"
41"
17 ¾"
18 ¾"
23"
19"
5"
Warm air supply
(top)
Return air supply
(side)
Model
Flue pipe
diam.
Furnace casing
@
0,25".w.c.
@
0,50".w.c.
@
0,25".w.c.
@
0,50".w.c.
95,200
81,000
0.68
MED-LOW MED-LOW
1165
1080
112,000
94,000
0.80
√
MED-HIGH MED-HIGH
1300
1200
95,200
81,000
0.68
112,000
94,000
0.80
√
Output
(BTU/h)
Firing
rate
(GPH)
PMP-112-DD
Model
PMP-112-VS
Input
(BTU/h)
Blower
motor HP
1/2 HP
ECM
10" x 10"
1/2 HP
4 speeds
Installed
Nozzle
See Table 13 page 19.
Blower motor Speed
adjustment
Blower CFM
Maximum
cooling
capacity
(tons)
3,5
Blower size
Model
Heating
temperature
rise (°F)
Filter quantity
and size
Volt - Hertz
- Phase
Electrical
load
(amps)
Minimum
ampacity for
wiring sizing
Maximum
fuse size
(amps)
Ship
weight
(pounds)
PMP-112-DD
55° - 75°
1 x 24" x 20"
115 - 60 - 1
12.6
15.2
20
153
PMP-112-VS
60° - 72°
1 x 24" x 20"
115 - 60 - 1
10.3
12.2
15
153