PMP
Oil Furnaces
–
Furnace Manual
670-000-003/1010
29
12
Dimensions and ratings
Model PMP-210, Burner data
Airflow data (CFM)
Pump
Combustion
pressure
air adjustment
BTU/h
(PSIG)
(band/shuttter)
168,000
1.20
1.00 - 80B
145
F6
No
2 3/4" (#3383)
0 / 6
189,000
1.35
1.10 - 80B
150
F6
No
2 3/4" (#3383)
1 / 3
210,000
1.50
1.25 - 80B
145
F6
No
2 3/4" (#3383)
1 / 5
Pump
pressure
BTU/h
(PSIG)
168,000
1.20
1.00 - 70W
145
189,000
1.35
1.10 - 70W
150
210,000
1.50
1.25 - 70W
145
Pump
pressure
Air Setting
BTU/h
(PSIG)
168,000
1,20
1.20 - 60B
100
1.10
189,000
1,35
1.35 - 60B
100
1.35
210,000
1,50
1.50 - 60B
100
1.50
PMP-210
1.10 / 1.25
1.35 / 1.50
1.35 / 1.50
CARLIN BURNER - EZ-1 - Tube insertion 2-1/2"
Model
Input
Firing rate
USGPH
Nozzle
(Delavan)
Head Setting "A"
BECKETT BURNER - Model AFG (3450 RPM) - Tube insertion 2 7/8"
Input
Model
Firing rate
USGPH
Nozzle
(Delavan)
Head
Low firing
rate baffle
Static disc
PMP-210
Model
Input
Firing rate
USGPH
RIELLO BURNER - Model 40-F5 - Tube insertion 3 9/16"
Combustion
air adjustment
(turbulator/band)
Nozzle
(Delavan)
0 / 3
PMP-210
1 / 3.25
4 / 4
0.1"
0.2"
0.3"
0.4"
0.5"
0.6"
0.7"
Med-High
2230
2210
2190
2170
2150
2110
2070
High
2390
2330
2270
2210
2150
2110
2070
Notes :
Airflow values in cubic ft per minute (CFM) rounded to nearest 5 CFM.
Data taken with filters in place.
PMP-210
External static pressure
Model
Blower speed