INSTALLATION AND
OPERATION MANUAL
PAGE
1
© Rev.
2/2021
1.800.428.4065
TOLL FREE
| www.willoughby-ind.com
WILLOUGHBY INDUSTRIES
ACCESSORY
IR FAUCET ASSEMBLY
SEE FOLLOWING PAGES FOR FAUCET
DIMENSIONS AND PART NUMBERS
LRFC
PART#:
703000IR / 703000BO
LIGATURE-RESISTANT IR FAUCET
STANDARD FEATURES
- Willoughby (LRFC) Ligature-resistant IR faucet is designed to allow users
to wash without the use of pushbuttons.
- Specifically for mental & behavioral healthcare facility use.
- Recommended operational pressure, 35-70 PSI.
DISASSEMBLY
1.
Unscrew the (2) 1/4-20 nuts on the all thread rod and take off the lock
washers and centering washers.
INSTALLATION
1. Make sure the deck gasket for the faucet is on the faucet and both
all-thread rods, PTC fitting, and wires for the IR valve are through the
gasket.
Note: Faucet can be mounted with or without the gasket and the
bottom edge sealed with non-pick caulking.
2. From the underside of the fixture, align the (2) 1/4-20 all-thread
rods with the mounting holes, making sure the PTC fitting and IR
sensor wires are going through the central hole.
3. Place the centering washer, lock washer and thread the nut onto the
all-thread rods (all included). Tighten the nuts down.
4.
After thorough flushing, connect the faucet to the water line from the
valve using the 3/8" PTC Fitting (included).
If you have Plug-In infrared sensors, go to Page 2.
If you have Battery Operated infrared sensors, go to Page 3.