background image

Page 3

Rev. 10/2016

www.willoughby-ind.com

Installation & Operation Manual

Outdoor Pet Drinking Fountain
WODF-1-PET Series

Willoughby Industries, Inc.

TOLL FREE 

(800) 428-4065

 

 LOCAL 

(317) 875-0830

 

 FAX 

(317) 875-0837

Pre-Installation Information

When installing the 

Willoughby Industries' WODF-1-PET Series

 fountain system:

Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location.

The valve assembly, including the spray head, 

MUST NOT BE 

connected until 

after 

all lines have 

been fl ushed to remove the small particles of debris that are inherent with new construction projects 
and all chemicals that are used in fl ushing are purged from the system.

Chemicals used in fl ushing plumbing systems can attack the internal components of the valve and 
spray head and severely damage them, so any fl ushing of the system must be followed by a full 
fl ushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if 
allowed to enter the valve assembly and spray head can cause poor performance or outright failure.

Again 

DO NOT 

attempt to connect the valve assembly and spray head until 

after

 all fl ushing is 

complete and pure water is the only media that will be passing through the system. Damage to the 
valve assembly or spray head caused by harsh chemicals or debris will not be covered by the 
manufacturer's warranty.

Any fi ttings provided by the installer should be made of plastic to electrically isolate the unit from the 
building or connected plumbing system.

The grounding of electric equipment such as telephones, computers, etc, to water lines is a common 
procedure. This grounding can cause electrical feedback into a water fountain or similar fi xture, 
causing electrolysis, which results in a metallic taste or an increase in the metal content of the water. 
This can easily be avoided by using the proper materials as indicated.

Installation notice!

Check Rough-In location 

PRIOR 

to installation

    Flush lines thoroughly 

PRIOR 

to hook-up

Installation notice!

Check Rough-In location 

PRIOR 

to installation

    Flush lines thoroughly 

PRIOR 

to hook-up

Summary of Contents for WODF-1-PET Series

Page 1: ...ntain Table of Contents Pre Installation Information 3 Physical Dimensions 4 Rough In Dimensions 5 Required Installation Supplies 6 Hardware Identification Chart 7 Installation Instructions Step 1 Fix...

Page 2: ...6 www willoughby ind com Installation Operation Manual Outdoor Pet Drinking Fountain WODF 1 PET Series Willoughby Industries Inc TOLL FREE 800 428 4065 LOCAL 317 875 0830 FAX 317 875 0837 Page intenti...

Page 3: ...s in the system if allowed to enter the valve assembly and spray head can cause poor performance or outright failure Again DO NOT attempt to connect the valve assembly and spray head until after all f...

Page 4: ...tion Manual Outdoor Pet Drinking Fountain WODF 1 PET Series Willoughby Industries Inc TOLL FREE 800 428 4065 LOCAL 317 875 0830 FAX 317 875 0837 Physical Dimensions WODF 1 PET 15 7 8 9 1 2 9 16 THRU A...

Page 5: ...DISCONNECTED AND DRAINED DURING WINTERIZATION PER THE FOLLOWING RECOMMENDED PRACTICES SHUT OFF WATER SUPPLY TO FIXTURE SUPPLY STOP AND WATER LINES BY OTHERS DISCONNECT AND REMOVE IN LINE FILTER PRESS...

Page 6: ...uired Installation Supplies Proper mounting hardware Proper plastic fittings as indicated Hardware for waste oulet connections Gasket for waste outlet connection Shims for installation if necessary Su...

Page 7: ...ughby Industries Inc TOLL FREE 800 428 4065 LOCAL 317 875 0830 FAX 317 875 0837 Hardware Identification Chart 1 4 20 x 1 2 SECURITY SCREW 4500NSS T27 1 4 PINNED TORX BIT 800115 1 4 20 x 2 FLAT HEAD SE...

Page 8: ...x 4 concrete anchors anchors not furnished 3 As noted previously flush the water supply line with clean drinking water before making final connections to the drinking fountain 4 Connect water supply l...

Page 9: ...emove valve box cover and push button together 3 Remove spring 4 Insert a standard flat head screwdriver into adjustment opening of valve as shown in Figure 4 5 Rotate screwdriver to adjust until desi...

Page 10: ...DVWHQ WKH FOHDQLQJ DFWLRQ IWHU VFUXEELQJ ULQVH 7 2528 DQG ZLSH GU 2 127 XVH FRPPRQ VWHHO ZRRO VFRXULQJ SDGV VFUDSHUV ZLUH EUXVKHV OHV RU RWKHU VWHHO WRROV WR clean stainless steel Such items will scra...

Page 11: ...pressure is too low flow can be drastically reduced 2 If pressure is too high the strainer and or valve may have been damaged 3 The unit is rated for a maximum range of 30 105 psi C Inspect the unit...

Page 12: ...DRAWING General Dimensions 15 7 8 9 1 2 9 16 THRU ALL 4X 14 1 2 4 1 4 12 1 2 BOLT CIRCLE 7 10 3 4 1 Indianapolis Indiana BEH EEF 3 16 15 10 08 14 C 1 OF 3 P0711 0003 1 5 2 PLCS SIZE OUTDOOR PET DRINKI...

Page 13: ...SECURITY SCREW 1 12 S200237 PET BOWL 1 3 4 DEPTH 1 13 980632 STRAINER IN LINE 1 4 TO 3 8 PRESS LOCK 1 14 380113 PUSH PIN FOR PET FOUNTAIN ADJUSTABLE PUSHBUTTON VALVE 1 15 800157 6 32 x 1 4 SH CAP SCR...

Page 14: ...Y OTHERS DISCONNECT AND REMOVE IN LINE FILTER PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS TO ALLOW WATER LINES TO DRAIN Indianapolis Indiana BEH EEF 3 16 15 10 08 14 C 3 OF 3 P0711 0003 1 8 PART 1 OUTDOO...

Page 15: ...oughby ind com Installation Operation Manual Outdoor Pet Drinking Fountain WODF 1 PET Series Willoughby Industries Inc TOLL FREE 800 428 4065 LOCAL 317 875 0830 FAX 317 875 0837 DRAWING Freeze Resista...

Page 16: ...al state and local building plumbing or electrical codes The warranty is limited to replacing or repairing at manufacturer s option transportation charges prepaid by the purchaser any component or par...

Reviews: