8
SM-275
SPECIFICATIONS
PROBLEM
CAUSE & SOLUTION
No power or Main Switch not lit up
when unit is plugged into power out-
let
Power is not on
—flip Main switch to ON position
GFCI Plug not reset
—press reset button on GFCI
GFCI Plug defective
Main switch defective
Main Switch lit up but motor not
turning when activated
Leakage in air-activated switch system
—defective Foot Pedal
—defective air switches
Defective motor
Short-circuit of wiring
Main Switch lit up & motor hums or
runs only in reverse when activated.
Defective air switches
—replace air switch
Motor running but Flexible Shaft not
turning
Broken Safety Coupling
Motor running but no water output
at end of Flexible Shaft
Water supply not turn on
Defective Solenoid Valve
Motor running and water drips in-
side unit
—Worn Teflon seal inside Motor Connector
—Leakage in tube or tube fittings
Unit running rough and/or noisy
Lack of lubrication in Motor Connector
—grease ball bearings inside Motor Connector
through grease fitting through access hole in
bottom of unit
—replace worn or corroded ball bearings in
Motor Connector
TROUBLE-SHOOTING
MODEL
9506-22
0
0
9600-2200
VOLTAGE
220
220
FREQUENCY
50
50
HORSEPOWER
1/2
1/2
RPM
1725
1725
WEIGHT (LBS)
35
55
DIMENSIONS
10”H 18”W 8 1/2”D 12”H 23”W 11 1/2”D
Thomas C. Wilson, LLC
21-11 44th Avenue, Long Island City, New York 11101
Tel: (800) 230-2636 Fax: (718)361-2872 http://www.tcwilson.com
E-mail: tcwilson@tcwilson.com
SM-275
Thomas C. Wilson, LLC
21-11 44th Avenue, Long Island City, New York 11101
Tel: (800) 230-2636 Fax: (718)361-2872 http://www.tcwilson.com
E-mail: tcwilson@tcwilson.com
TO REDUCE THE RISK OF INJURY AND EQUIPMENT DAMAGE
USER MUST READ AND UNDERSTAND OPERATOR’S MANUAL.
Rev: A, 1/20/2015
OPERATING INSTRUCTIONS
&
SERVICE MANUAL
WILS-AWAY
ELECTRIC TUBE CLEANER
9506-22
0
0
9600-2200