away from heat, oil, or sharp edges. Protect it from breaking. Do not pull out the plug by pulling
the power cable.
•
If the compressor is used outdoors, only approved extensions may be used. Every wire of the
extension cable must have at least a 1,5
mm² cross-section.
•
Store the compressor in a well-ventilated place. Do not allow children or any other people not
able to handle this device to play or work with it.
•
Be very careful when working with the compressor. Do not perform work with this product when
being unalert or influenced by alcohol, drugs, or medicine.
•
When beginning work, make sure that all screws are tightened.
•
Do not use the compressor if it is damaged. If the compressor makes unusual noises and strong
vibrations or if other unusual signs occur that indicate some damage, immediately turn off the
compressor. Do not modify the compressor in any way. Only have repairs made by qualified
persons and using original spare parts.
Properties
•
Oil-free diaphragm compressor, no polluted air
•
Overheating protection
•
Very low noise level
Use
The AS06 airbrush compressor is for example suitable for operating in the following areas: arts and
crafts, hobbies, modelling, tattoos and body art, make-up, and nail design, as a source of air in the field
of medicine, in food industry, chemical industry, laboratories, etc.
Technical specifications
Type
Diaphragm compressor
Power
(W)
250 (¼
hp)
Rotation speed
(
r
⁄
min
)
1450–1700
Flow rate
(
ℓ
⁄
min
)
65–68
Pressure range
(
㍴
)
0–3.5
Weight
(
㎏
)
4.5
Size
(
㎜
)
255×125×170
Suitable nozzles
(
㎜
)
0.2–1.0
Sound level
(dB (A))
approx. 40
Length of cable
(m)
1.9
Hose connection
(
㎜
)
13 (¼″)
User notes
•
The compressor has a 13
mm (¼″) outlet, which can be effortlessly changed to ⅛″. The matching
adapter is not included in the delivery.
•
When the compressor is connected by the hose to the airbrush gun, it can be connected to the
mains and switched on.
•
The maximum pressure is displayed the pressure gauge, the operating pressure can be ad-
justed by the pressure regulator.