background image

  

© by WilTec Wildanger Technik GmbH  

 

Seite 12  

http://www.WilTec.de 
http://www.aoyue.eu

 

Version 3.2016

 

http://www.teichtip.de 

 
 
The  information  contained  in this  document  is  subject  to  change  without  prior  notice.  No  part  of this 
document can be copied or duplicated in another form without

 

the prior written consent of WilTec Wil-

danger  Technik  GmbH.  The  WilTec  Wildanger  Technik  GmbH  assumes  no  liability  for  any  errors  in 
this user manual or the connection diagram. 
Although WilTec Wildanger Technik GmbH has made every effort to make sure that this user manual 
is  complete,  accurate  and  updated,  errors  cannot  always  be  avoided.  In  the  event  of  problems  with 
this user manual please complete and send this form back to us. 
 

 

FAX-notification (++

+49 2403 55592-15

), 

 

 

 

from: ________________________________________

 

 

 

Name: 

________________ 

  

Firm:

_____________________ 

  

Tel/Fax:

__________________ 

  

I would like to report the following mistakes: 

 

 

 

 

 

 

 

  
 
 
 
 
 
 
 

 
___________________________________________________________________ 
  

Customer Service WilTec Wildanger Technik GmbH  
e-mail: 

service@WilTec.info

 

Tel:++ +49 2403 55592-0 

Introduction 

 
Thank  you  for  purchasing  this  quality  product.

 To  minimize  the  risk  of  injury  by  means  of  fire  or 

electric  shock  we  urge  that  our  clients  take  some  basic  safety  precautions  when  using  this 
device. Please read the operation instructions carefully and make sure you have understood its 
content.

 

Always use a grounded power connection with the appropriate mains voltage. You can find the corre-
sponding mains voltage on the type plate. If you have any doubts about the connection being ground-
ed, have it checked by a qualified professional. Never use a faulty electric cable. 
Do not inspect the electrical part of the pressure pond filter in a wet or damp environment or when you 
are wet yourself and protect it from direct sunlight. Install this device in a safe location so that nobody 
can  step  on  the  cable,  fall  over  or  damage  it.  Disconnect  the  power  plug  before  cleaning it  and  use 
only a damp cloth for cleaning. Avoid using cleaning agents and make sure that no liquid enters the 
electrical part of the pump. 
The electric part of the device contains no parts that can be inspected or serviced by the user. Leave 
the maintenance, adjustment and repair to qualified technical personnel. In case of unauthorised inter-
vention the 2-year warranty is no longer valid! Keep these operation instructions safe. 
 

 

Summary of Contents for 34203

Page 1: ...RTICLE 34203 Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificant ly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...ank you for purchasing this quality product To minimize the risk of injury by means of fire or electric shock we urge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corre sponding mains ...

Page 3: ...evice if the safety ap pliances are damaged or worn out Never override safety regulations Use the device exclusively according to the intended purpose stated in the instructions for use You are responsible for the safety of the working environment If the cable or the plug is damaged due to external influences the cable must not be repaired It has to be replaced with a new one This work can be carr...

Page 4: ... not pull the power cable in order to unplug it from the power socket If the compressor is used outdoors only approved extensions may be used Every wire of the extension cable must have at least 1 5 mm2 cross section Do not store the compressor with the plug inserted into the plug Do not allow children or any other people who are not able to handle this device to play or work with it Be very caref...

Page 5: ...d by a tape made teflon Testing of leakage Switch on the compressor and wait until the maximum pressure has built up and the auto stop function has been activated If there is no leakage the pressure gauge should display nearly constantly the same range of pres sure A quick decrease of the range of pressure suggests that there is in fact a leakage It is of great importance to seal any leak as soon ...

Page 6: ...essure and helps generating clean dry pressure stable air The regulator can be used only according to the operating instructions Operation o The manometer reports the working pressure of the air tool o Pull up the adjusting knob its clockwise rotation increases the pressure and a counter clockwise rotation reduces the pressure o Rotate the adjusting knob to achieve the right working pressure and f...

Page 7: ...OR 2 30 AF18 31 PRESSURE SWITCH 1 8 AF18 09 FRONT BODY 1 31 AF18 32 WATER RELEASE NEDDLE 1 9 AF18 10 COUNTERWEIGHT 1 32 AF18 33 CONDENSER 1 10 AF18 11 MANOMETER 1 33 AF18 34 POWER SWITCH 1 11 AF18 12 BEARING 1 34 AF18 35 WIRE 1 12 AF18 13 RETAINIER RING 1 35 AF18 36 RUBBER PAD 4 13 AF18 14 COMPRESSION RING 1 36 AF18 37 HEXAGON NUT 1 14 AF18 17 CYLINDER 1 37 AF18 38 CONNECTOR 2 17 AF18 18 VALVE PLA...

Page 8: ...opean countries with a separate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this article you protect the environment and the health of your f...

Reviews: