background image

  

© by WilTec Wildanger Technik GmbH  

Item 34204 

Page 2 

 

http://www.WilTec.

de

 

http://www.aoyue.eu   

   

07 2021

-1

 

http://www.teichtip.de

 

 
The information contained in this document may alter at any time without prior notice. No part of this 
document may be copied or otherwise duplicated without prior written consent. All rights reserved. 
WilTec  Wildanger  Technik  GmbH  cannot  be  held  liable  for  any  possible  mistakes  in  this  operating 
manual, nor in the diagrams and illustrations shown. 
Although WilTec Wildanger Technik GmbH has made every possible effort to ensure that this operating 
manual is complete, accurate and up-to-date, errors cannot be ruled out entirely. 
If you have found an error or wish to suggest an improvement, we look forward to hearing from you. 
Send us an e-mail to: 
 

service@wiltec.info

 

 
or use our contact form: 
 

https://www.wiltec.de/contacts/

 

 
The most recent version of this manual in several languages can be found in our online shop: 
 

https://www.wiltec.de/docsearch

 

 
 
Our postal address is: 
 
WilTec Wildanger Technik GmbH 
Königsbenden 12 
52249 Eschweiler Germany 
 
Do you wish to collect your goods? Our address for collection is: 
 
WilTec Wildanger Technik GmbH 
Königsbenden 28 
52249 Eschweiler Germany 
 
In order to shorten the waiting time and to allow for an easy on-site processing, we kindly ask you to 
contact us briefly beforehand or to place your order via the webshop. 
 
E-mail: service@wiltec.info 
Phone: +49 2403 55592-0 
Fax: +49 2403 55592-15 
 
To  return  your  goods  for  exchange,  repair  or  other  purposes,  please  use  the  following  address. 
Attention! To allow for a trouble-free complaint or return, it is important to contact our customer service 
team before returning your goods. 
 
Retourenabteilung 
WilTec Wildanger Technik GmbH 
Königsbenden 28 
52249 Eschweiler Germany 
 
E-mail: 

service@wiltec.info

 

Phone: +49 2403 55592-0 
Fax: (+49 2403 55592-15) 
 

 

Summary of Contents for 34204

Page 1: ... may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments ...

Page 2: ...https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to collect your goods Our address for collection is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany In order to shorten t...

Page 3: ...le or the plug is damaged due to external influences the cable must not be repaired but has to be replaced with a new one This work can only be carried out by an electrician The voltage of 230 V AC indicated on the nameplate of the device must match the existent mains voltage Never lift transport or suspend the device by its power cord Make sure that the electrical plug connection is protected fro...

Page 4: ...eing unalert or influenced by alcohol drugs or medicine When beginning work make sure that all screws are tightened Do not use the compressor if it is damaged If the compressor makes unusual noises and strong vibrations or if other unusual signs occur that indicate some damage immediately turn off the compressor Do not modify the compressor in any way Only have repairs made by qualified persons an...

Page 5: ...aled by sealing tape Leakage check Switch on the compressor and wait until the maximum pressure has built up and the auto stop function has been activated If there is no leakage the pressure gauge should display nearly constantly the same range of pressure A quick decrease of the range of pressure suggests that there is in fact a leakage It is of great importance to seal any leak as soon as possib...

Page 6: ...ntrol the pressure and helps generating clean dry and stable air pressure The regulator can only be used according to the operating instructions Operation 1 The pressure gauge reports the working pressure of the air tool 2 Pull up the adjusting knob a clockwise rotation increases the pressure a counter clockwise rotation reduces the pressure 3 Rotate the adjusting knob to achieve the right working...

Page 7: ... 34204 Page 7 http www WilTec de http www aoyue eu 07 2021 1 http www teichtip de Construction Name 1 Handle 2 Casing 3 Pressure controller 4 Main switch 5 Cover 6 Ventilation 7 Mains plug 8 Water filter 9 Pressure gauge 10 Connection point ...

Page 8: ...assembly disassembly made by the user Reinstall cylinder valve and place it in the right direction Engine runs but makes noises Bearings are loose or damaged Replace bearings Screws in connecting rod loose Tighten or replace screws Airbrush gun does not function properly insufficient blowing pressure Air connection not tight Seal air connection with insulating tape Air hose torn off Re mount the a...

Page 9: ...tor 23 Filter 37 Hexagon head nut 7 Bearing 24 O ring 38 Connection 8 Rotary motor 25 Cylinder block 39 Connection piece 9 Front main unit 26 O ring 41 Pressure gauge 10 Counterweight 27 Cylinder head 46 Rotor 11 Pressure gauge 28 Screw washer 47 Plug 12 Bearing 29 Filter valve 48 Holder unit 13 Retainer ring 30 Handle 49 Airbrush gun holder 14 Compression ring 31 Pressure switch 17 Cylinder 32 Wa...

Page 10: ...ountries of the European Union and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indicates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the prot...

Reviews: