Introduction

 

 
Thank you for choosing to purchase this quality product. To minimise the risk of injury, we ask you to 
always take some basic safety precautions when using this product. Please read this operating manual 
carefully and make sure that you understand it. 
Keep these operation instructions in a safe place. 
 
 

Safety instructions

 

 

 Caution! 

 

 

The  use  of  this  device  is  only  allowed  with  a  fault  current  protection  switch  with  a  triggering 
nominal current up to 30 mA (according to VDE 0100 Article 702 and 738). 

 

The device is not intended for use by persons (including children) with impaired or limited phys-
ical, sensory and mental abilities or lack of experience and/or real knowledge, unless they are 
supervised by a person responsible for their safety or follow the instructions made by this person 
on how to correctly use the device. 

 

Children should be supervised to ensure that they do not play with the device. 

 

 Attention! 

 

 

The compressor head can become very hot. 

Burning hazard!

 

 

Perform a visual inspection of the device before every use. Do not use the device if the safety 
appliances are damaged or worn out. Never override safety regulations. 

 

Only use the device accordingly to the intended purpose stated in this manual. 

 

You are responsible for the safety of the working zone. 

 

If the cable or the plug is damaged due to external influences, the cable must not be repaired, 
but has to be replaced with a new one. This work can only be carried out by an electrician. 

 

The  voltage  of  230 V  AC  indicated  on  the  nameplate  of  the  device  must  match  the  existent 
mains voltage. 

 

Never lift, transport, or suspend the device by its power cord. 

 

Make sure that the electrical plug connection is protected from flood and moisture. 

 

Before any maintenance work or adjustment, pull out the plug. 

 

The user is responsible for complying with local safety and mounting regulations. Ask an elec-
trician if you have questions. 

 

In case of device failure, repairs can only be carried out by an electrician. 

 

 Notes! 

 

 

Choose  the  right  compressor  with  the  appropriate  air  volume  and  air  pressure  to  match  the 
actual work requirements. 

 

Never expose the device to dust, acid, steam, explosive or flammable gases, or weather influ-
ences (rain, sun, fog, snow). 

 

The vacuum pump can only be operated in an appropriate environment (good ventilation, am-
bient tempe5 

–+40 

). 

 

Never use the compressor barefoot or with wet hands or feet. 

 

Never allow children to touch the switched-on compressor or to insert the plug. It may cause 
burns or electric shocks. 

 

Do not open or damage any part of the compressor. If necessary, contact a qualified person. 

 

By opening the drain valve, the water can be evacuated. Always release the water before not 
using the compressor for a long time. Store the compressor in a well-ventilated place. 

 

Always wear protective goggles. Under no circumstances should you direct the airflow towards 
your body or other persons’ bodies or animals. 

Summary of Contents for 34207

Page 1: ...r may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments ...

Page 2: ...https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to collect your goods Our address for collection is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany In order to shorten t...

Page 3: ...e or the plug is damaged due to external influences the cable must not be repaired but has to be replaced with a new one This work can only be carried out by an electrician The voltage of 230 V AC indicated on the nameplate of the device must match the existent mains voltage Never lift transport or suspend the device by its power cord Make sure that the electrical plug connection is protected from...

Page 4: ...ing work make sure that all screws are tightened Do not use the compressor if it is damaged If the compressor makes unusual noises and strong vibrations or if other unusual signs occur that indicate some damage immediately turn off the compressor Do not modify the compressor in any way Only have repairs made by qualified persons and using original spare parts Properties Air tank emits regular puls...

Page 5: ...ons should be sealed by sealing tape Leakage check Switch on the compressor and wait until the maximum pressure has built up and the auto stop function has been activated If there is no leakage the pressure gauge should display nearly constantly the same range of pressure A quick decrease of the range of pressure suggests that there is in fact a leakage It is of great importance to seal any leak a...

Page 6: ...ntrol the pressure and helps generating clean dry and stable air pressure The regulator can only be used according to the operating instructions Operation 1 The pressure gauge reports the working pressure of the air tool 2 Pull up the adjusting knob a clockwise rotation increases the pressure a counter clockwise rotation reduces the pressure 3 Rotate the adjusting knob to achieve the right working...

Page 7: ...lTec de http www aoyue eu 07 2021 1 http www teichtip de Assembly Name Double switch 1 Handle Position 1 autostop at 4 bar Position 2 maximum pressure at 6 bar 2 Airbrush gun holder 3 Pressure regulator 4 Pressure gauge 5 Air outlet 6 Water drain plug 7 Mains plug ...

Page 8: ...ssembly disassembly made by the user Reinstall cylinder valve and place it in the right direction Engine runs but makes noises Bearings are loose or damaged Replace bearings Screws in connecting rod loose Tighten or replace screws Airbrush gun does not function properly insufficient blowing pressure Air connection not tight Seal air connection with insulat ing tape Air hose torn off Re mount the a...

Page 9: ...Screw 39 Connection piece 3 Block 21 Front gasket 40 Adaptor 4 Rear main unit 22 Front cover 41 Pressure controller 5 Screw 23 Filter 42 Container 6 Stationary motor 24 O ring 43 Three way manifold 7 Bearing 25 Cylinder block 44 Three way manifold 8 Rotary motor 26 O ring 45 Check valve 9 Front main unit 27 Cylinder head 46 Hose nut 10 Counterweight 29 Filter valve 47 Plug 11 Pressure gauge 30 Han...

Page 10: ...eichtip de 12 Bearing 31 Pressure switch 49 Safety valve 13 Retainer ring 32 Water release needle 50 Drain valve 14 Compression ring 33 Capacitor 51 Adaptor 15 Hose 34 On off switch 52 Hose 16 Solenoid valve 35 Wire 53 Screw nut 17 Cylinder 36 Rubber pad 54 Base plate 18 Valve plate 37 Hexagon head nut 55 Cover ...

Page 11: ...untries of the European Union and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the prot...

Reviews: