Warning!

 A potential hazard that could cause serious injury or loss of life:

Do not weld on the air tank of this compressor. Welding on the air compressor tank can cause
an extremely hazardous condition. Welding on the tank in any manner will void the warranty.

Never use an electric air compressor outdoors when it is raining or on a wet surface, as it may
cause an electric shock.

This unit starts automatically. 

Always

 turn the compressor off, remove the plug from the out-

let, and release all pressure from the system before servicing the compressor, and when the
compressor is not in use.

Check the manufacturer’s maximum pressure rating for air tools and equipment. The com-
pressor outlet pressure must be regulated to never exceed the maximum pressure rating of
the tool.

High temperatures and moving parts are located under the guard. To prevent burns or other
injuries, do  

not

  operate with the guard removed. Allow the compressor parts to cool before

handling or servicing them.

Be certain to read all labels when you are spraying paints or toxic materials and follow the
safety instructions. Use a respirator mask if there is a risk of inhaling anything you are spray -
ing. Read all instructions and be sure that your respirator mask will protect you.

Always wear safety goggles or glasses when using an air compressor. Never point any nozzle
or sprayer toward a person, an animal or any part of the body.

Do not adjust the pressure switch or regulating valve for any reason. Doing so voids all war-
ranties. They have been pre-set at the factory for the maximum pressure of this unit.

Caution!

 A potential hazard that may cause moderate injury or damage to equipment:

Drain the moisture from the tank on a daily basis. A clean, dry tank will help prevent corrosion.

Pull the pressure relief valve ring daily to ensure that the valve is functioning properly and to
clear of any possible blockages.

To provide proper ventilation for cooling, the compressor must be kept a minimum of 31 cm
(12 inches) from the nearest wall and in a well-ventilated area.

Fasten the compressor down securely if transport is necessary. The pressure must be re-
leased from the tank before transport.

Protect the air hose and electrical wire from damage and puncture. Inspect them weekly for
weak or worn spots, and replace them if necessary.

Warning:

 

Disconnect power and release all pressure from the system before attempting to install, ser-

vice, relocate or perform any maintenance.

Follow all local electrical and safety codes as well as National Electrical Codes (NEC) and Oc-
cupational Safety and Health Act (OSHA).

Electric motors and starters must be securely and adequately grounded using a three-pronged
outlet.

Caution: 

Never use an extension cable with this product. Use an additional air hose instead of an ex -

tension cable to avoid power loss and permanent motor damage. Use of an extension cable voids the
warranty.

Brief Description

This micro air compressor is of novel design and excellent workmanship. Having the advantages of
compact construction, fine design, light weight, easy operation, high safety and low noise, it can be
widely used in  machinery,  chemical  industry,  spray and decoration, automatic control system and
other fields where compressed air is required.

© by WilTec Wildanger Technik GmbH 

Item 61016

Page 4 

http://www.WilTec.de
http://www.aoyue.eu

 

11 2020

-1

http://www.teichtip.de

Summary of Contents for 61016

Page 1: ...instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...anguages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or pla...

Page 3: ...al tape when working with air fittings to prevent leakage Introduction Read this manual carefully before operating or servicing this air compressor to familiarize with proper safety operating and maintenance procedures Failure to comply with instructions in this manual could result in personal injury property damage and will void your warranty Following the instructions in this manual will provide...

Page 4: ...it Caution A potential hazard that may cause moderate injury or damage to equipment Drain the moisture from the tank on a daily basis A clean dry tank will help prevent corrosion Pull the pressure relief valve ring daily to ensure that the valve is functioning properly and to clear of any possible blockages To provide proper ventilation for cooling the compressor must be kept a minimum of 31 cm 12...

Page 5: ...et weight 27 kg Preparation for starting The place to set the compressor should be clean dry and ventilated Keep the voltage within 5 of the rated one Keep the oil level on the level of the red circle Use compressor oil SAE30 or L DAB 100 over 10 and use SAE10 or L DAB68 be low 10 Open the outlet valve set the pressure switch knob in the on position fig 2 let the compressor run for 10 minutes with...

Page 6: ...to be stopped when running you only need to set the pressure switch knob into the off position Fig 2 Caution Put the cover off first and put on the air pipe and air filter before running the compressor fig 3 Never unscrew any connecting part the tank being under pressure Never disassemble any electrical part before disconnecting the plug Never adjust the safety valve carelessly Never use the compr...

Page 7: ...new the lubricating oil after the first 10 working hours Check the oil level after every 20 working hours and refill it if necessary Open the drain cock under the tank to exhaust any condensate after every 60 working hours Clean crankcase after every 120 working hours and renew the oil clean the air filter and check the safety valve and the pressure gauge by WilTec Wildanger Technik GmbH Item 6101...

Page 8: ... Heavy shaking or unusual noise Connecting part loosened Foreign body got into main compressor Piston knocking valve seat Moving parts seriously worn Check and re tighten Check and clean away Replace with thicker pa per gasket Repair or replace Pressure insufficient or discharge capacity de creased Motor runs too slow Air filter blocked Leakage of safety valve Leakage of discharge pipe Sealing gas...

Page 9: ...Exploded view by WilTec Wildanger Technik GmbH Item 61016 Page 9 http www WilTec de http www aoyue eu 11 2020 1 http www teichtip de ...

Page 10: ...sure switch 1 14 Connecting rod 1 42 Pressure gauge 1 15 Rubber gasket 1 43 Outlet valve 2 16 Screw M5 14 6 44 Switch bracket 1 17 Crank case cover 1 45 Connector nut 1 18 Oil reservoir washer 1 46 Discharge connect 1 19 Oil level indicator 1 47 Check valve 1 20 Bolt M8 22 1 48 Air tank 1 21 Crank 1 49 Bolt M8 25 1 22 Crank case 1 50 Washer foot 1 23 Motor 1 51 Washer 8 1 24 Sealing ring 1 52 Nut ...

Page 11: ...nts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consum...

Page 12: ...Cet appareil est conforme aux directives européennes 2006 42 EC 2014 35 EU 2014 30 EU Es ist nach folgenden harmonisierten Normen geprüft worden It has been tested with the following harmonised standards Il a été testé à partir des normes harmonisées suivantes EN ISO 12100 2010 EN 1012 1 2010 EN 60204 1 2006 A1 2009 AC 2010 EN 61000 6 1 2007 EN 61000 6 3 2007 A1 2011 AC 2012 EN 61000 3 2 2014 EN 6...

Reviews: