background image

The information contained in this document is subject to change without prior notice. No part of this
document can be copied or duplicated in another form without

 

the prior written consent of  WilTec

Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liability for any errors in
this user manual or the connection diagram.
Although WilTec Wildanger Technik GmbH has made every effort to make sure that this user manual
is complete, accurate and updated, errors cannot always be avoided.  In the event of problems with
this user manual please complete and send this form back to us.

FAX-notification (++

+49 2403 55592-15

), 

 
from: ________________________________________
 
Name: 

________________

 

Firm:

_____________________

 

Tel/Fax:

__________________

 

I would like to report the following mistakes: 

 
 
 
 

_______________________________

 

 ____________________________________

 

 

 

Customer Service WilTec Wildanger Technik GmbH 
e-mail: 

service@WilTec.info

Tel:++ +49 2403 55592-0

Introduction

Thank you for purchasing this quality product.

 To minimize the risk of injury by means of fire or

electric shock we urge that our clients take some basic safety precautions when using this
device. Please read the operation instructions carefully and make sure you have understood its
content.

Always   use   a   grounded   power   connection   with   the   appropriate   mains   voltage.   You   can   find   the
corresponding mains voltage on the type plate. If you have any doubts about the connection being
grounded, have it checked by a qualified professional. Never use a faulty electric cable.
Do not inspect the electrical part of the pressure pond filter in a wet or damp environment or when you
are wet yourself and protect it from direct sunlight. Install this device in a safe location so that nobody
can step on the cable, fall over or damage it. Disconnect the power plug before cleaning it and use
only a damp cloth for cleaning. Avoid using cleaning agents and make sure that no liquid enters the
electrical part of the pump.
The electric part of the device contains no parts that can be inspected or serviced by the user. Leave
the   maintenance,   adjustment   and   repair   to   qualified   technical   personnel.   In   case   of   unauthorised
intervention the 2-year warranty is no longer valid! Keep these operation instructions safe.

© by WilTec Wildanger Technik GmbH 

Seite 18 

http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de

Summary of Contents for 61134

Page 1: ...ime Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us by WilTec Wildanger Technik GmbH Seite 17 http www WilTec de http www aoyue eu http www teichtip de ...

Page 2: ...ck we urge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corresponding mains voltage on the type plate If you have any doubts about the connection being grounded have it checked by a qu...

Page 3: ...g hair These items can get caught in moving parts causing serious personal injury Stay alert watch what you are doing and never operate the tool while being tired or under the in fluence of drugs alcohol or medication A moment of inattention while operating the tool increases the risk of injury to persons Remove adjusting keys and wrenches before switching the tool on A wrench or a key that is lef...

Page 4: ... use brake fluids gasoline petroleum based products or any strong sol vents to clean your tool Do not use the tool as hammer Never use gasoline or flammable liquids to clean the tool Never use the tool in the presence of flammable liquids or gases Vapors can be ignited by a spark and cause an explosion that will re sult in death or serious personal injury Do not remove or manipulate the trigger Ne...

Page 5: ...tions discussed in this manual cannot cover all possible conditions and situations that may occur Always be aware and cautious while working with the tool Only use it with accessories that are rated to handle the forces exerted by this tool during opera tion Other accessories which are not designed for the generated forces may break and forcefully launch pieces Attach all accessories properly to t...

Page 6: ... servicing the tool o When tool is not in use o When moving to a different work area as accidental actuation may occur causing injury Never connect the tool to an air source that may exceed 90 PSI Over pressurizing the tool may result in bursting abnormal operation breakage of the tool as well as serious personal injury Use only clean dry regulated compressed air at the rated pressure or within th...

Page 7: ...et 4 5m is ideal Do not use bottled air or gases Please see below Fig 2 All compressed air contains moisture and other contaminants that can harm the internal components of the tool An air filter will remove most of these and signifi cantly extend the life of the tool Ensure the in line oiler has sufficient oil If an in line oiler is not available place 2 drops of oil into the tool s air inlet at ...

Page 8: ... the work area moving the tool to another location or handing it to another person PREPARING THE TOOL Drain water from the air compressor tank and any condensation from air lines Please refer to the op eration manual of the air compressor Lubricate the tool Please refer to the maintenance section in this manual Select the necessary impact sockets The sockets must match the size of the drive on the...

Page 9: ...rse tool operation 5 Adjust the air flow by pushing down the air regulator and turn ing knob from positions 1 to 4 Fig 2 aligning the desired number setting with the recessed arrow Position 1 allows the lowest amount of air flow Position 4 allows the highest amount of air flow 6 Push and snap the required 1 2 drive impact socket not included onto the anvil CAUTION Keep tool pointed in a safe direc...

Page 10: ...RE EACH USE inspect the general condition of the tool Check for o Loose hardware or housing o Misalignment or binding of moving parts o Cracked or broken parts o Any other condition that may affect its safe condition Daily Air supply Maintenance Every day maintain the air supply according to the component manufacturers instructions Maintain the lubricator s oil level Drain the moisture filter regu...

Page 11: ...r in air supply as stated in Setup Air Supply Severe air leakage Slight air leakage is normal especially on older tools 1 Cross threaded hous ing components 2 Loose housing 3 Damaged valve or housing 4 Dirty worn or damaged valve 1 Check for incorrect alignment and uneven gaps If cross threaded disassemble and replace damaged parts before using the tool 2 Tighten the housing assembly If housing ca...

Page 12: ...ng Repairs must only be made by an authorized service partner or the manufacturer Do not open or disassemble the power tool by WilTec Wildanger Technik GmbH Seite 28 http www WilTec de http www aoyue eu http www teichtip de ...

Page 13: ... Dog 31 Trigger 10 Hammer Cage 32 Pin 11 Drive Cam 33 Screw 12 Ball Bearing 34 Spring 13 Front End Plate 35 O Ring 14 Rotor Blade 36 Air Regulator 15 Rotor 37 Valve Stem 16 Pin 38 Steel Ball 17 Cylinder 39 Spring 18 Pin Cylinder 40 Hose Adapter 19 Rear End Plate 41 Valve Sleeve 20 Ball Bearing 42 Reverse Valve 21 Rear Gasket 43 Bushing 22 Rear Cover by WilTec Wildanger Technik GmbH Seite 29 http w...

Page 14: ...ackaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce th...

Reviews: