© by WilTec Wildanger Technik GmbH
Item 909378pro
Page 8
12 2022-1
7.
Repeatedly press the Set button until the display shows “SAVE.” Press the Up button to save
the value and exit system configuration mode.
8.
The tip is now properly calibrated.
9.
Saved settings remain saved and in effect unless changed by the user.
Quick access setting
The system has two adjustable quick access settings. The quick access functions allow the user to
easily jump to a previously set temperature. The two most commonly used temperatures must first be
stored in the system. With a simple press of two buttons, the system will automatically jump to these
pre-set temperature levels. To set these two quick access temperature levels:
1.
Press and hold the Set button to enter system configuration mode.
2.
Repeatedly press the Set button until the display shows a number preceded by a “b.” This
means that you can now set the first quick access value.
3.
Select the desired quick access temperature by pressing the Up or Down button.
4.
To set the second quick access value, press the Set button repeatedly until a number preceded
by a “C” appears. This means that the second quick access value can now be set.
5.
Select the desired quick access temperature by pressing the Up or Down button.
6.
To save the adjusted values, press the Set button repeatedly until the display shows “SAVE.”
Press the Down button to save the value and exit system configuration mode.
7.
The two quick access values are now set and can now be called up as follows: the first quick
access value by pressing the Up button and the Set button at the same time, the second quick
access value by pressing the Down button and the Set button at the same time.
Up and Set button
First quick access value
b350 (pre-setting)
Down and Set button
Second quick access value
C430 (pre-setting)
Sleep function setting
The soldering iron is equipped with a vibration sensor. When the soldering iron is not moved, the system
starts counting down the idle time. A lowercase d is now displayed in the first digit, which means that
the system is preparing to enter sleep mode. Four dashes (“- - - -”) will appear on the display panel to
indicate that the system has entered sleep mode. To wake up the system, simply lift the soldering iron
or press any control button. The sleep countdown time can be set as follows:
1.
With the device powered on, press and hold the Set button to enter the system configuration
mode.
2.
Repeatedly press the Set button until a number preceded by a “t” or “t000” is displayed. This
means that you can now set the sleep countdown time.
3.
The display “t000” means that the sleep function is currently switched off. To adjust the count-
down value, press the Up or Down button. The sleep countdown time is adjustable from 2 to
60
min.