© by WilTec Wildanger Technik GmbH
Item 909378pro
Page 9
12 2022-1
4.
To save the adjusted values, press the Set button repeatedly until the display shows “SAVE.”
Press the Down button to save the value and exit system configuration mode.
System lock setting
The system lock function disables the setting of temperature and system configuration. The display
shows “SAFE” when the system lock function is on. To unlock the system, press and hold all three
buttons simultaneously for more than 15 s. To enable the system lock feature:
1.
With the device powered on, press and hold the Set button to enter the system configuration
mode.
2.
Press the adjustment button repeatedly until “LOFF” is displayed. This means that you can now
set the system lock.
3.
“LOFF” means that the system lock feature is currently off. To activate the system lock, press
the Down button to switch the lock function to “LOn.”
4.
To save the system lock settings and activate the lock, press the Set button repeatedly until the
display shows “SAVE.” Press the Down button to save the value and exit system configuration
mode.
5.
“SAFE” will appear on the display, which means that the system lock is activated.
When the system lock is on, changes to the temperature and system settings are made impossible. The
system lock must first be unlocked to allow access to the system again. How to turn off the system lock
again:
1.
With the device powered on, press and hold the Up button, the Set button, and the Down button
for more than 15 s.
2.
The display changes from “SAFE” to the set temperature value when the system lock has been
released.
Selection of the temperature scale
The displayed temperature can be switched between the Celsius and Fahrenheit scale. To do this,
proceed as follows:
1.
With the device powered on, press and hold the Set button to enter the system configuration
mode.
2.
Press the adjustment button repeatedly until “
℃
” or “°F” is displayed. This means that the tem-
perature scale can now be adjusted.
3.
“
℃
” means that the temperature is displayed in degrees Celsius. “°F” means that the tempera-
ture is displayed in degrees Fahrenheit. Press the Up or Down button to toggle between the two
temperature scales.
4.
To save the temperature scale setting, press the Set button repeatedly until the display shows
“SAVE.” Press the Up button to save the value and exit system configuration mode.
The temperature display changes according to the selected scale. “F” / “###F” means the temper-
ature is displayed in degrees Fahrenheit, “C” / “###C” means the temperature is displayed in degrees
Celsius.
LED on/off
Only for tools with LED functionality. To toggle between on and off:
1.
With the device powered on, press and hold the Set button to enter the system configuration
mode.
2.
Press the Set button repeatedly until “POFF” is displayed. This means that the LED on/off set-
ting can now be configured. Press Up and Down button to choose between ON and OFF.
3.
“OFF” indicates that the LED is off, “ON” indicates that the LED is on.