Leak checks

 

 

 

Switch on the compressor and wait until the maximum pressure has built up and the auto-stop 
function has been activated. 

 

If there is no leak, the pressure gauge should show the same pressure range almost constantly. 

 

A rapidly decreasing pressure area indicates an actual leak. 

 

It is very important to seal a leak as soon as possible to avoid affecting the performance and 
efficiency of the compressor. 

 

A leak means that the auto-stop and auto-start functions are activated permanently. 

 
 

Difference between maximum and service pressure

 

 

 

The maximum pressure is the highest possible pressure that a compressor can generate. 

 

As soon as the maximum pressure is reached, the compressor switches off (auto-stop). As soon 
as the pressure begins to drop, it switches on again (auto-start). 

 

The maximum pressure is the pressure measured in the compressor itself. 

 

The pressure at the compressor outlet is lower. The pressure remains that you actually work 
with. This working pressure can vary depending on the connected airbrush gun. 

 
 

Operation of pressure regulator with filter

 

 
 

a) Pressure regulator 
b) Pressure gauge 
c) Water drain plug 
 
 
 
 
 
 
 
 
 
 
 
 

Product name:

  

Pressure regulator with filter and pressure gauge 

Type:   

 

AFR-2000 

 

Properties:

 

The AFR-2000 is an in-line low pressure regulator with 9 bar (100 psi); it includes a pressure gauge and 
a  water  drain  plug.  Thanks  to  this  regulator  the  user  can  control  the  pressure  and  helps  to  produce 
clean, dry, and stable compressed air. The controller may only be used in accordance with the operating 
instructions. 
 

Operation:

 

1.  The pressure gauge shows the working pressure of the pneumatic tool. 
2.  Pull the adjustment knob upwards; a clockwise turn increases the pressure; a counter-clockwise 

turn decreases it. 

3.  Turn the adjustment knob to have the correct working pressure and snap it back into place. 
4.  Do not turn the rotary knob against excessive resistance. If necessary, the height and position 

of the rotary knob can be varied slightly. 

5.  Use the water drain plug to empty the condensate collector. 

 

 

Summary of Contents for AF18-2

Page 1: ...ating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...ice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweil...

Page 3: ...must not be repaired but must be replaced with a new one This work may only be performed by a qualified electrician The 230 V alternate voltage stated on the nameplate of the device must correspond to the existing mains voltage Never lift carry or suspend the device by its power cord Make sure that the electrical plug connections are protected from flood and moisture Pull out the plug before any a...

Page 4: ...tions or other unusual signs that indicate damage immediately stop the compressor Do not make any structural changes to the compressor Only have repairs carried out by qualified specialists and with original spare parts Properties Compressor with pressure reducer condensate drain and pressure gauge Oil free piston compressor no contaminated air With water filter pressure setting and pressure gauge...

Page 5: ... itself The pressure at the compressor outlet is lower The pressure remains that you actually work with This working pressure can vary depending on the connected airbrush gun Operation of pressure regulator with filter a Pressure regulator b Pressure gauge c Water drain plug Product name Pressure regulator with filter and pressure gauge Type AFR 2000 Properties The AFR 2000 is an in line low press...

Page 6: ...chnik GmbH Item 34203 Page 6 http www WilTec de http www aoyue eu 05 2021 1 http www teichtip de Assembly Name 1 Pressure regulator 2 Connection 3 Pressure gauge 4 Air filter 5 Power plug 6 Fan 7 Cover 8 Power switch 9 Handle ...

Page 7: ...4 Power switch 5 Screw 21 Front gasket 35 Cable 6 Stationary motor 22 Cover 36 Rubber pad 7 Bearing 23 Filter 37 Hexagon nut 8 Rotary motor 24 O ring 38 Plug 9 Front cover 25 Cylinder block 39 Connection rod 10 Counterweight 26 O ring 41 Pressure regulator 11 Pressure gauge 27 Cylinder head 46 Fan 12 Bearing 28 Cylinder screw 47 Holder support 13 Retainer ring 29 Filter 48 Cover 14 Compression rin...

Page 8: ... European countries with a separate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your ...

Reviews: