© by WilTec Wildanger Technik GmbH
Item 34203
Page 5
05 2021
-1
Leak checks
•
Switch on the compressor and wait until the maximum pressure has built up and the auto-stop
function has been activated.
•
If there is no leak, the pressure gauge should show the same pressure range almost constantly.
•
A rapidly decreasing pressure area indicates an actual leak.
•
It is very important to seal a leak as soon as possible to avoid affecting the performance and
efficiency of the compressor.
•
A leak means that the auto-stop and auto-start functions are activated permanently.
Difference between maximum and service pressure
•
The maximum pressure is the highest possible pressure that a compressor can generate.
•
As soon as the maximum pressure is reached, the compressor switches off (auto-stop). As soon
as the pressure begins to drop, it switches on again (auto-start).
•
The maximum pressure is the pressure measured in the compressor itself.
•
The pressure at the compressor outlet is lower. The pressure remains that you actually work
with. This working pressure can vary depending on the connected airbrush gun.
Operation of pressure regulator with filter
a) Pressure regulator
b) Pressure gauge
c) Water drain plug
Product name:
Pressure regulator with filter and pressure gauge
Type:
AFR-2000
Properties:
The AFR-2000 is an in-line low pressure regulator with 9 bar (100 psi); it includes a pressure gauge and
a water drain plug. Thanks to this regulator the user can control the pressure and helps to produce
clean, dry, and stable compressed air. The controller may only be used in accordance with the operating
instructions.
Operation:
1. The pressure gauge shows the working pressure of the pneumatic tool.
2. Pull the adjustment knob upwards; a clockwise turn increases the pressure; a counter-clockwise
turn decreases it.
3. Turn the adjustment knob to have the correct working pressure and snap it back into place.
4. Do not turn the rotary knob against excessive resistance. If necessary, the height and position
of the rotary knob can be varied slightly.
5. Use the water drain plug to empty the condensate collector.