Selecting
Step Sweep
Mode
In step sweep frequency mode, the output frequency
changes in discrete, synthesized steps between se-
lected start and stop frequencies. The step size or
number of steps between the start and stop frequen-
cies and the dwell time-per-step are controllable
from a step sweep menu.
To place the 681XXA in step sweep frequency mode,
press the main menu key
CW/SWEEP
SELECT
At the resulting menu display, press
Step
. The
Step Sweep Menu (shown below) is then displayed.
This menu lets you perform the following:
Select a sweep range (edit the sweep start and
stop frequency parameters).
Go to the sweep ramp menu (set the dwell
time-per-step, the step size or number of steps,
and select a sweep trigger).
Select a marker mode.
Go to the alternate sweep menu.
LOCAL (FRONT
SWEEP FREQUENCY
PANEL) OPERATION
OPERATION
681XXA OM
3-25