30 Shower panel
WimTec OCEAN P7
EN
OCEAN P7
Shower panel
SanTec OCEAN P7
30
Stagnation rinse:
DIP-switch 6
Program description
Serves to remove stagnant water that accumulates during longer periods of
disuse.
Dip-switch 6 ON = Stagnation rinse enabled.
Dip-switch 6 OFF = Stagnation rinse disabled (default setting).
Time interval
Can be set from 3–48 h at the
interval control (see page 20).
Automatic stagnation rinse
If the fitting has not been used
for the set period, the stagnati-
on rinse operation is automati-
cally executed for 10 s.
Safety
If there is an user in the active
area or the cleaning stop is
enabled, the stagnation rinse-
starts 2 min after deactivation.
5 s before and after the
stagnation rinse the vertical
line of the ON/OFF icon pulses
quickly.
3
-
48
h
10
s
30-70 cm