30 Shower control
SanTec PROOF S6
EN
PROOF S6
Cleaning stop:
DIP switch 5
Description of the functions
Serves to disable the fitting prior to cleaning.
Dip switch 5 ON = Cleaning stop enabled (default setting).
Dip switch 5 OFF = Cleaning stop disabled.
User detection
When you step in front of the
shower, the system will detect
you.
Enable cleaning stop
Approach the infrared sensor
with your hand (see image).
for 2 s. In the meantime, use
your free hand to tap the ON/
OFF icon and thus enable the
cleaning stop. The cleaning
stop remains enabled for
10 min after leaving the sensor
range.
Disable cleaning stop
The function automatically
stops if no user was detected
for 10 minutes.
You can manually disable the
function following the same
procedure used to enable it.
The fitting will resume normal
operation with a safety delay
of 3 s after you leave the
sensor range.
1 2 3 4 5 6
ON
OFF
Halbautomatik:
Vollautomatik:
Manuell:
Warmlauf:
ON
OFF
1 2 3
4
5 6
ON
OFF
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
Reinigungsstopp:
ON
OFF
1 2 3 4
5
6
Hygienespülung:
ON
OFF
1 2 3 4 5
6
30-70 cm