background image

Winchester Gas Furnace

 

 

 

 

 

 

 

 Installation Instructions

Winchester by Mortex Products Inc. / Fort Worth, TX 76106

   

 

 

WG   Installation Instructions

13

WG BLOWER PERFORMANCE CHART

 

 

ESP INCHES WC DUCT

 

SPD TAP

0.1

0.2

0.3

0.4

0.5

H2/10 OR (00) BLOWER - 10 X 8 WHEEL 1/4 HP 2 SPD MOTOR

 

 

CFM-NO-COIL 

LO

940

885

835

780

725

HI

1225 1165 1110 1030

970

CFM-WITH-COIL 

LO

865

825

775

730

670

HI

1105 1050 1010

930

870

 

 

A3/12 OR (42) BLOWER - 10 X 8 WHEEL 1/3 HP 3 SPD MOTOR 

(Accessory PN 87-1008-312A1)

 

 

 

 

 

 

CFM-NO-COIL 

LO

980

950

910

875

825

MED

1220 1170 1120 1065 1015

HI

1460 1400 1340 1270 1195

CFM-WITH-COIL 

LO

945

905

865

815

775

MED

1130 1085 1030

970

905

HI

1300 1240 1180 1105 1085

 

 

A4/16 OR (60) BLOWER - 10 X 8 WHEEL 3/4 HP 4 SPD MOTOR 

(Accessory PN 87-1008-316A1)

 

 

 

 

 

 

CFM-NO-COIL 

LO

995

960

915

875

825

MED

1205 1165 1130 1090 1045

MED-HI

1470 1425 1385 1345 1310

HI

1810 1765 1720 1680 1635

CFM-WITH-COIL 

LO

950

905

885

835

790

MED

1145 1115 1080 1035 1000

MED-HI

1375 1345 1315 1280 1245

HI

1700 1660 1620 1575 1540

Summary of Contents for WG SERIES

Page 1: ...ranty CHECKLIST FURNACE START UP 1 Has furnace roof jack crown been correctly installed 2 Has the furnace gas valve and burner orifice been cleaned 3 Is the gas line outlet pressure set for the fuel u...

Page 2: ...0 X 1 For elevations above 2 000 feet reduce input 4 for each 1 000 ft elevation above sea level Must Use RJS Roof Jack for Sloped Roof or RJF Roof Jack for Flat Roof 1 2 FPT 115 VAC 60 Hz 1 PH 15 Amp...

Page 3: ...ATION STANDARDS CODE COMPLIANCE The installer shall become familiar with and follow all local codes and regulations which govern the installation of this furnace Where applicable local codes may take...

Page 4: ...The cross sectional area of the return system when located in the floor or ceiling of the manufactured home leading into the closet is to be not less than that of the opening specified on the applian...

Page 5: ...Winchester by Mortex Products Inc Fort Worth TX 76106 WG Installation Instructions Winchester Gas Furnace Installation Instructions 5...

Page 6: ...Furnace Installation Instructions Winchester by Mortex Products Inc Fort Worth TX 76106 WG Installation Instructions 6 FIG E Duct Connector 90 DCU0 01 1 4 90 DCU0 01 6 8 90 DCU0 01 8 12 FIG E Duct Con...

Page 7: ...bring in outside combustion air for the burner 7 Do not install furnace with any other type of venting system A HAZARDOUS CONDITION MAY RESULT FURNACE W COIL CASE SIDE VIEW FURNACE W COIL CASE SIDE V...

Page 8: ...e 7 collar 5 Check and make sure the combustion air pipe is fully seated Then drive a 10 sheet metal screw attaching pipe firmly to furnace collar 6 Install optional ceiling trim ring 90 TRM RNG 7 On...

Page 9: ...d a door Choose a location where the temerature will be reasonbly representative of other living areas the thermostat is controlling CONNECT THERMOSTAT WIRES When installing a furnace with a cooling c...

Page 10: ...input to the furnace is too high due to excessive pressure wrong size burner orifice no orifice high altitude etc the burner flame will be sooty especially with Propane gas This type of furnace operat...

Page 11: ...SIZE PART NO ORIF DIA DRILL SIZE PART NO ORIF DIA DRILL SIZE PART NO ORIF DIA DRILL SIZE SEA LEVEL 75AG 086 0 086 44 75AG 0935 0 0935 42 75AG 096 0 096 41 75AG 104 0 104 37 2000 75AG 082 0 082 45 75AG...

Page 12: ...ning is installed 2 Check to make sure that electrical power is on at the furnace and the furnce breaker has not tripped 3 Make sure that the filters are clean and return grills are not obstructed The...

Page 13: ...12 OR 42 BLOWER 10 X 8 WHEEL 1 3 HP 3 SPD MOTOR Accessory PN 87 1008 312A1 CFM NO COIL LO 980 950 910 875 825 MED 1220 1170 1120 1065 1015 HI 1460 1400 1340 1270 1195 CFM WITH COIL LO 945 905 865 815...

Page 14: ...uctions HEAT ONLY MODELS UTEC TI BOARD WIRING DIAGRAM FLASH CODES 1 FLASH IGNITION FAILURE 2 FLASHES STEADY ON 3 FLASHES 4 FLASHES 5 FLASHES NORMAL OPERATION COMBUSTION AIR SWITCH FAILED TO CLOSE COMB...

Page 15: ...OARD WIRING DIAGRAM FLASH CODES 1 FLASH IGNITION FAILURE 2 FLASHES STEADY ON 3 FLASHES 4 FLASHES 5 FLASHES NORMAL OPERATION COMBUSTION AIR SWITCH FAILED TO CLOSE COMBUSTION AIR SWITCH STUCK CLOSED LIM...

Page 16: ...ons COROLA BOARD WIRING DIAGRAM FLASH CODES 1 FLASH IGNITION FAILURE 2 FLASHES STEADY ON 3 FLASHES 4 FLASHES 5 FLASHES NORMAL OPERATION COMBUSTION AIR SWITCH FAILED TO CLOSE COMBUSTION AIR SWITCH STUC...

Reviews: