background image

3

OPM-135/C

 

  a well ventilated area.

 

F. Follow local codes for closeness to combustible 

   material.

3. DEADLY EXHAUST GAS - 

Exhaust fumes from any gasoline engine contain carbon 

monoxide, an invisible, odorless and deadly gas that must 

be mixed with fresh air.

 

A. Operate only in well ventilated areas.

 

B. Never operate indoors including attached garages

 

C. Never operate the unit in such a way as to allow 

 

  exhaust gases to seep back into closed rooms (i.e. 

 

  through windows, walls, floors).

4. NOISE HAZARD - 

Excessive noise is not only tiring, but continual exposure 

can lead to loss of hearing.

 

A. Use hearing protection when working around this 

 

  equipment for long periods of time.

 

B. Keep your neighbors in mind when using this 

   equipment.

5. CLEANLINESS - 

Keep the generator and surrounding area clean.

 

A. Remove all grease, ice, snow or materials that create 

 

  slippery conditions around the unit.

 

B. Remove any rags or other materials that could create 

 

  a  potential fire hazard.

 

C. Carefully clean up any gas or oil spills before starting 

 

  the unit.

6. SERVICING EQUIPMENT -

All service, including the installation or replacement of 

service parts, should be performed only by a qualified 

technician.

 

A. Use only factory approved repair parts.

 

B. Do not work on this equipment when fatigued.

 

C. Never remove the protective guards, covers, or 

 

  receptacle panels while the engine is running.

 

D. Use extreme caution when working on electrical 

 

  components. High output voltage from this 

 

  equipment can cause serious injury or death.

 

E. Always avoid hot mufflers, exhaust manifolds, and 

 

  engine parts. They can cause severe burns instantly.

 

F. The use of the engine-generator set must comply 

 

  with all national, state, and local codes.

SAFETY INFORMATION

This engine generator set has been designed and 

manufactured to allow safe, reliable performance. Poor 

maintenance, improper or careless use can result in 

potentially deadly hazards; from electrical shock, exhaust 

gas asphyxiation, or fire. Please read all safety instructions 

carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all 

warnings on the unit labels and in the manuals.

CALIFORNIA PROPOSITION 65

WARNING: This product contains crude oil, 

gasoline, diesel fuel and other petroleum 

products, Antifreeze to which can expose you 

to chemicals including toluene and benzene, 

Ethylene glycol (ingested) which are known to 

the State of California to cause cancer, birth defects or other 

reproductive harm and developmental issues. 

For more information go to www.P65Warning.ca.gov.

ANSI SAFETY DEFINITIONS

DANGER:

DANGER indicates an imminently hazardous situation 

which, if not avoided, will result in death or serious injury. 

This signal word is to be limited to the most extreme 

situations.

WARNING:

WARNING indicates a potentially hazardous situation 

which, if not avoided, could result in death or serious injury.

CAUTION:

CAUTION indicates a potentially hazardous situation which, 

if not avoided, may result in minor or moderate injury. It 

may also be used to alert against unsafe practices.

1. ELECTRICAL SHOCK -

The output voltage present in this equipment can cause 

fatal electric shock. This equipment must be operated by a 

responsible person.

 

A. Do not allow anyone to operate the generator 

 

  without proper instruction.

 

B. Guard against electric shock.

 

C. Avoid contact with live terminals or receptacles.

 

D. Use extreme care if operating this unit in rain or 

   snow.

 

E. Use only three-pronged grounded receptacles

 

  and extension cords.

 

F. Be sure the unit is properly grounded to an

 

  external ground rod driven into the earth.

2. FIRE HAZARD - 

Gasoline and other fuels present a hazard of possible 

explosion and/or fire.

 

 

A. Do not refuel when the engine is running or hot.

 

B. Keep fuel containers out of reach of children.

 

C. Do not smoke or use open flame near the generator 

 

  set or fuel tank.

 

D. Keep a fire extinguisher nearby and know its proper 

 

  use. Fire extinguishers rated ABC by NFPA are 

   appropriate.

 

E. Store fuel only in an approved container, and only in 

Summary of Contents for DR20I4-/1 Series

Page 1: ...AL 1 DEG ANGULAR 9 15 2016 ZJF COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours If you should ever need to contact us on this unit it will help us to...

Page 2: ...FILTER CLEANING RADIATOR CHANGING THE FUEL FILTER STORAGE MAINTENANCE SCHEDULE TROUBLESHOOTING TABLE 16 ENGINE HARNESS SCHEMATIC 17 WIRING SIZE TABLE 17 DSE7310 WIRING DIAGRAM 18 WIRING DIAGRAMS 19 LI...

Page 3: ...k exhaust gas asphyxiation or fire Please read all safety instructions carefully before installation or use Keep these instructions handy for future reference Take special note and follow all warnings...

Page 4: ...everal of the major components also have their own individual data plates providing additional information to document build data for warranty and replacements parts Be sure to have the main WINCO uni...

Page 5: ...enerator for operation take a couple of minutes to ensure the unit you have received is the correct model and review the specification pages in this manual to ensure that this unit meets your job requ...

Page 6: ...aller The factory weather enclosures are acoustical housing intended for outdoor installation only Factory weather enclosed units are not intended to be used indoors and no support is available to ass...

Page 7: ...pipe to aid your installation Ensure proper alignment with the generator The flex can be eliminated if it is pushed to one side to make a connection The most direct path possible should be used to ge...

Page 8: ...ert the wire into the larger circular hole B Remove the screwdriver to secure the wire into place A B A C ELECTRICAL CONNECTIONS NOTICE CLASS 1 WIRING METHODS ARE TO BE USED FOR ALL FIELD WIRING CONNE...

Page 9: ...ries of remote accessories that can help provide useful information to operators These accessories communicate over the DSE Net Terminal blocks are wired to the distribution panel to aid in installati...

Page 10: ...must be clean and tight Depending on your battery type check the electrolyte in the battery periodically to be sure it is above the plates Never allow the battery to remain in a discharged condition...

Page 11: ...N PERSONAL INJURY Only check oil when the engine is not running and is at a low temperature in order to avoid the risk of burns 1 Remove the dipstick and ensure the oil level is between the Min and Ma...

Page 12: ...AC On three phase panels the G2 voltage level should also be checked ON 240 VOLT DELTA SYSTEMS BE SURE YOU KNOW WHERE THE HIGH VOLTAGE WILD LEG IS IT MUST BE IN THE SAME LOCATION ON THE LINE SIDE AS I...

Page 13: ...not connected to a battery charger A solar charger kit is the easiest way to always maintain the battery during storage in mobile applications The supplied battery charger can be plugged in to an exte...

Page 14: ...O NOT dispose or allow oil to seep into the ground or sewer systems doing so will cause environmental damage CHANGING OIL FILTER The filter must be replaced when the lubricant oil is changed Only use...

Page 15: ...iquid in accordance to local codes DO NOT dispose or allow liquid to seep into the ground or sewer systems doing so will cause environmental damage CLEANING RADIATOR The surfaces of the radiator come...

Page 16: ...citer stator AC short in the output leads Defective open generator output breaker Wiring error protective liquid ISO 4113 and introduce the liquid by pressurizing the circuit and driving the engine fo...

Page 17: ...418 431 458 480 519 550 572 585 50 68 86 100 118 137 155 177 205 237 264 291 319 346 391 432 473 487 505 532 560 605 642 669 683 8 6 4 3 2 1 1 0 2 0 3 0 4 0 250 300 350 400 500 600 700 750 800 900 100...

Page 18: ...18 OPM 135 C DSE7310 WIRING DIAGRAM...

Page 19: ...WIRING DELTA SINGLE PHASE 120 240 VOLTS SINGLE PHASE AC WIRING 4 LEAD WIRING DIAGRAMS 24 60708 165 THREE PHASE AC WIRING HIGH AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS THREE PHASE HIGH WYE 277 480...

Page 20: ...omponent of the product that is no longer manufactured or available Additionally WINCO Inc will not be liable for any engine replacement that may require an emissions tier level change THERE ARE NO EX...

Reviews: