background image

Summary of Contents for BEETLE /?-II

Page 1: ...BEETLE M II with Embedded Scale Controller and 2 Displays Technical Information ...

Page 2: ...is not permitted without express authority Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility model or design are reserved Delivery subject to availability technical modifications possible Copyright Wincor Nixdorf International GmbH 2005 Published by Wincor Nixdorf International GmbH D 33094 Paderborn ...

Page 3: ... scale can be connected This module processes all scale data from tare specification to zero setting The embedded scale controller is internally connected to a multiplexer card VGA 4 MUX PCI so that the scale data can be displayed at the customer cashier display BA69 The display BA69W with tare and zero button must be connected to the LCD2 socket of the multiplexer card For security reasons the sc...

Page 4: ..._______________________________________________________________ _____________________________________________________________________ 2 Interior View Embedded Scale Controller Emb Scale Controller HD FD Power Supply Fan ...

Page 5: ..._____________________________________________________________________ _________________________________________________________________ 3 VGA 4 MUX PCI Controller VGA 4 MUX PCI Controller Embedded Scale Controller ...

Page 6: ..._____________________ _____________________________________________________________________ 4 Backside Scale Connection Calibration Seal Calibra tion Switch Connection for COM4 BA69 Display Connection BA69W Display Connection Connection COM4 to Scale Controller ...

Page 7: ...at the side ventilation slots of the BEETLE M II are not blocked thus ensuring that the device always has sufficient ventilation Mind the minimum clearances indicated below If you plan to install the unit into a confined space always be sure to maintain the specified minimum clearance and ensure constant air flow for effective ventilation The immediate ambient temperature for the system must not e...

Page 8: ...cient ventilation upwards 50 mm downwards 50 mm A vertically installed device therefore has to be placed on a rig spacer made of non combustible material that guarantees sufficient ventilation and a minimum clearance of 50 mm to the bottom of the furniture A surface made of nonflammable material e g concrete or metal must be located underneath the vertically mounted BEETLE Install the equipment so...

Page 9: ...tions Footprint Width Depth w o cable cover 288 mm 286 mm Height 155 mm Weigth approx 7 kg depending on the installation Weight of battery with panel approx 930 g Power consumption typical 3A 5A max Line voltage frequency 50 60 Hz Noise generation 47 dB A Power input ratings 100 120 V 2A max 200 240 V 1A max Operating temperature EN 60721 3 3 class 3k3 Environmental test IEC 68 EN60068 Air tempera...

Page 10: ...ments EN 60721 3 1 class 1k2 Environmental test IEC 68 EN60068 Air temperature 5 C to 40 C Humidity 5 r h 1g m 3 85 r h 25 g m 3 0 5 K min Temperature fluctuation 0 5 K min max 7 5K 30min Transport requirements EN 60721 3 2 class 2k2 Environmental test IEC 68 EN60068 Air temperature 25 C to 60 C Humidity 15 r h 1 g m 3 98 r h 32 g m 3 Temperature fluctuation 25 C 25 C ...

Page 11: ..._________________________________________________ 9 Manufacturer Certification This device fulfills the requirements of EU Regulations 89 336 EWG Electromagnetic Compatibility and 73 23 EWG Low Voltage Guidelines The device carries the CE logo on its rear side or the logo is located on the packaging ...