Function and Integration
Procedures in the CMD-V4
01750060162 A
Cash Media Dispenser Version 4 - Service Manual
2-11
Procedures in the CMD-V4
Start-up behavior
With a reset or after power-up it is checked whether the CMD-V4 is ready to
operate. This is only the case if the command is executed without errors!
After device reset, the CMD-V4 is in a defined status.
Execution of the command is cancelled when the first error is detected. The
causes of errors can be seen on the controller's status display (see the
"Troubleshooting" chapter).
Controller test
A reset uses the same routine as power-up in principle but the controller test is
not performed. The controller test takes about six seconds and is finished
when <--> appears on the status display. In the event of an error, processing is
aborted with status code <10> (controller defective).
Firmware tt
The validity of the loaded firmware is checked. Processing may be aborted
with status code <11> (firmware missing).
Memory reset
The internal markers are reset.
In addition to the general memory area, there are program and parameter
areas the contents of which are retained by means of a support battery if a
power failure occurs.