Installation
Installation with 25 mm (0.98") installation frame
01750058390 G
ProCash 2050xe USB - Installation Guide
97
Mounting structure for installation on screed
CE
N
UL
(m
in
. 1.57")
min. 40
25
(0
.98")
min. 125
(min. 4.92")
*
2
4
6
7
1
3
8
5
1 Safe
5 Screed
2 Mounting set for safe
6 Concrete
3 Tear-off sensor
7 Mounting set for installation frame
4 Installation frame
8 Top surface of finished floor
*
The overall drilling depth depends on the structural conditions. The
threaded rods must be anchored at least 125 mm (4.92") in the load-
bearing concrete.
Excess lengths must be shortened correspondingly or, if necessary in
case of deeper floor anchorages, be replaced by equivalent threaded
rods.