Installation with height-adjustable installation rack
Installation
130
ProCash 2050xe USB - Installation Guide
01750058390 G
i
Installation on raised or cavity flooring as well as on a floating floor is
not permissible according to the CEN standard. If the mounting
structure differs from the one described below (see illustration below),
it must be approved by the insurer.
To ensure that the safe does not become detached, the threaded rods
of the installation rack must be fastened in the concrete foundation.
The drilled holes in the concrete foundation must have a depth of at
least 125 mm (4.92") for the installation rack (see illustration below).
For the hole diameter please refer to the mounting instructions of the
caulking cartridge.
The drilled hole in the concrete foundation must have a depth of at
least 40 mm (1.57") for the tear-off sensor (see illustration below).
Consult your alarm technician about the size of the hole and the fixing.