Shortening the cables
Installing the Remote Status Indicator
168
ProCash 2050xe USB - Installation Guide
01750058390 G
Release the four terminals of the
terminal strip and disconnect the cable
from the terminal strip (1).
Remove the connecting cable with the
spacer from cable guide (2).
Remove the spacer from the
connecting cable (see arrow).
Shorten the connecting cable to the
desired length.
Push the spacer back on the cable.
•
Shorten the cable end as shown in the following diagram.
25
(0.98")
4.5
(0.18")
You must strip approx. 25 mm (0.98")
of the cable insulation and 4.5 mm
(0.18") of the individual wire insulation.
The individual wire ends must be
twisted.